The Current Limitations and Future Direction of Instrument Design for Totally Endoscopic Ear Surgery: a Needs
Arushri Swarup1,2, Gavin J le Nobel1,3, Jan Andrysek2
1Department of Otolaryngology Head and Neck Surgery, Hospital for Sick Children.
Objective:
This study aimed to identify limitations and challenges associated with existing instruments and techniques used in totally endoscopic ear surgery (TEES).
Background:
Otologic instruments, traditionally developed for two-handed surgery with operating microscopes, are not necessarily optimized for the TEES environment. Better understanding of technical challenges and the limitations of current instrumentation may allow advances in instrument design for TEES surgery.
Methods:
This cross-sectional study employed a mixed-methods nine-question survey that was distributed internationally to surgeons with an interest in TEES. Respondents were asked to classify their TEES experience and instrumentation used, rate their need for better instrumentation to address six TEES-related challenges using visual analog scales, and comment on how to modify or develop new instrumentation.
Results:
With 51 respondents, we quantified a need for better instruments to address the following 6 potential TEES challenges ordered from greatest to least need: 1) reaching structures visualized by the endoscope, 2) dissection and removal of cholesteatoma, 3) cutting and/or removing bone, 4) bleeding control, 5) keeping the endoscope lens clean, 6) moving and positioning a graft into the intended place. The majority of surgeons perceive a need for improved instrumentation to address each challenge. Challenges 1) and 2) were associated with significantly greater need than the others (p < 0.05, Wilcoxon method for nonparametric pairwise comparisons).
Conclusion:
In addition to highlighting and quantifying some of the common TEES challenges, these findings provide valuable insight into the design requirements for developing improved surgical instrumentation and techniques.
Related Concept Videos
Surveys
Evaluating Limits by Direct Substitution
Introduction to Surveying, Plane Surveying and Geodetic Surveys
Uncertainty in Measurement: Reading Instruments
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Limiting Reactant