Anatomic Feasibility of Distal Fibula Bicortical Screw Fixation With Lateral Neutralization Plating for Rotational Ankle Fractures
Related Experiment Video
Updated: Feb 9, 2026

Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018
Laura E Sansosti1, Andrew J Meyr2
1Resident, Podiatric Surgical Residency Program, Temple University Hospital, Philadelphia, PA.
Abstract:
A common technique for fixation of rotational fibular fractures is to use an interfragmentary compression screw with a laterally positioned neutralization plate. The objective of the present investigation was to examine the anatomic feasibility of distal fibula bicortical fixation within this plating technique. A specific screw insertion technique was performed through a laterally positioned one-third tubular plate on a consecutive series of 81 intact cadaveric ankle mortises. The most distal plate hole was drilled, aimed 10° posterior to the midline of the fibula. The second-most distal plate hole was drilled, aimed 25° superiorly. The specimens were then dissected, and the screw termini were physically examined for whether they had penetrated the articular cartilage of the ankle mortise. The length of the most distal bicortical screw measured a mean ± standard deviation of 20.44 ± 2.49 (range 14 to 26) mm, with an extra-articular terminus in 95.06% of specimens. The length of the second-most distal bicortical screw measured a mean ± standard deviation of 19.68 ± 3.02 (range 12 to 28) mm, with an extra-articular terminus in 100% of the specimens. The results of the present study provide evidence that bicortical distal fibular fixation in accordance with basic fixation principles is anatomically possible and feasible with a one-third tubular plate. This could potentially obviate the need for more expensive fixation options (i.e., locked plates or anatomically contoured plates) and fixation options that are biomechanically stable but potentially anatomically impeding (i.e., posterior antiglide plating).
More Related Videos
12:25C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
Related Concept Videos
Ankle Joint
Bones of the Lower Limb: Tibia and Fibula
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Acids, Bases and Neutralization Reactions