Blood Pressure Measurement and Left Ventricular Mass Index in Hemodialysis Patients: Comparison of Several Methods
Amir Ahmad Nassiri, Legha Lotfollahi1, Neda Behzadnia
1Division of Nephrology, Department of Medicine, Hasheminejad Kidney Center, Iran University of Medical Sciences; National research Institute of Tuberculosis and Lung Diseases, Shahid Beheshti University of Medical Sciences; Tehran, Iran. leghalotfollahi@yahoo.com.
Introduction:
Systemic arterial hypertension is prevalent in end-stage renal disease and is closely associated with left ventricular hypertrophy (LVH). Blood pressure (BP) behavior is unique in this population, and it is not clear which BP measurement should be used for treatment guidance. We aimed to evaluate the association of several methods of BP measurement with left ventricular mass index (LVMI) as hypertensive end-organ damage.
Materials And Methods:
Patients on maintenance hemodialysis, 3 or 4 times per week for at least 3 months, were enrolled. We compared the diagnostic value of 6 different methods of BP measurement, including predialysis, postdialysis, interdialysis, and standard BP measurements as well as ambulatory blood pressure monitoring (ABPM) and home blood pressure monitoring, based on LVMI as the gold standard.
Results:
Twenty patients, including 9 women and 11 men were enrolled. Ten patients (50%) had LVH and the others had normal LVMI (LVMI > 100 g/m2 for women and > 131 100 g/m2 for men). Only predialysis and postdialysis systolic BP values were significantly associated with LVMI (P = .02 and P = .02, respectively).
Conclusions:
Predialysis and postdialysis systolic BP values maybe reliable for detecting hypertension in hemodialysis patients, although according to previous data, the importance of self and ambulatory BP monitoring could not be overlooked.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...