Publisher Correction: Precisely printable and biocompatible silk fibroin bioink for digital light processing 3D
Soon Hee Kim1, Yeung Kyu Yeon1, Jung Min Lee1
1Nano-Bio Regenerative Medical Institute, College of Medicine, Hallym University, Chuncheon, 24252, Republic of Korea.
Nature Communications
|June 13, 2018
Abstract:
The original version of this Article contained errors in Figs. 5 and 6. In Fig. 5b, the second panel on the bottom row was stretched out of proportion. In Fig. 6d, the first panel was also stretched out of proportion. In Fig. 6f, the fifth panel inadvertently repeated the fourth. This has been corrected in both the PDF and HTML versions of the Article.
Related Concept Videos
Distance Corrections
297
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
297
Uncertainty in Measurement: Accuracy and Precision
102.9K
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value.
102.9K
Power Factor Correction
547
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
547
Accuracy and Precision
15.5K
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. Highly accurate...
15.5K
NMR Spectrometers: Resolution and Error Correction
1.1K
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.1K
Light Acquisition
9.6K
In order to produce glucose, plants need to capture sufficient light energy. Many modern plants have evolved leaves specialized for light acquisition. Leaves can be only millimeters in width or tens of meters wide, depending on the environment. Due to competition for sunlight, evolution has driven the evolution of increasingly larger leaves and taller plants, to avoid shading by their neighbors with contaminant elaboration of root architecture and mechanisms to transport water and nutrients.
9.6K


