The Accuracy of Cone-Beam Computed Tomography for Evaluating Bone Density and Cortical Bone Thickness at the Implant
Srisurang Suttapreyasri1, Pradipat Suapear, Narit Leepong
1Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand.
Abstract:
The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) for determining cortical thickness and the gray value, investigating its correlation with micro-computed tomography (CT) and histology analysis. Sixty-two bone samples from 4 anatomic regions of the jaw were analyzed. A radiographic surgical stent was used during CBCT and bone sample harvesting. The cortical thickness and gray value of the planned implant were evaluated by CBCT. Bone volumetric fractions, bone mineral density, and % porosity assessed by micro-CT and mineralized material by histology analysis from harvested bone samples were analyzed and assessed for the association with the CBCT using Pearson correlation. A correlation between cortical thickness measured from the CBCT and Micro-CT (r = 0.933, P < 0.01) was identified. There was no difference between gray values measured from the CBCT among regions, while bone density parameters from micro-CT and histologic analysis showed significant difference (P < 0.01) among regions. Bone density parameters from micro-CT and histologic analysis showed correlation with cortical thickness but not with the gray value. In conclusion, CBCT is highly accurate in linear measurements and demonstrated correlation with genuine bone density. However, the gray value could not demonstrate the true bone density according to a low correlation to bone density variable measured from micro-CT and histologic analysis.
More Related Videos
04:24Proper Positioning and Restraint of a Rat Hind Limb for Focused High Resolution Imaging of Bone Micro-architecture Using In Vivo Micro-computed Tomography
Published on: November 22, 2017
10:50Osmotic Drug Delivery to Ischemic Hindlimbs and Perfusion of Vasculature with Microfil for Micro-Computed Tomography Imaging
Published on: June 29, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Design Example: Traverse Angle Computations
Bone Structure
Bone Remodeling
Compact Bone
Compact bone, also called cortical bone, is the denser, stronger of the two types of bone tissue. It is found under the periosteum and in the diaphyses of long bones, where it provides support and protection. The microscopic structural unit of compact bone is called an osteon, or haversian system. Each osteon is composed of concentric rings of calcified...