Related Experiment Video
Updated: Feb 9, 2026

04:34
Modified Spared Nerve Injury Surgery Model of Neuropathic Pain in Mice
Published on: January 25, 2022
6.9K
Neuronal loss in anterior cingulate cortex in spared nerve injury model of neuropathic pain
Wei Tan1, Wen-Long Yao1, Bo Zhang1
1Department of Anesthesiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
Neurochemistry International
|June 13, 2018
Abstract
No abstract available in PubMed .
Related Concept Videos
Spare Receptors
4.6K
Some receptors remain unoccupied even when an agonist produces a maximal response. Such empty ones are called spare receptors. In presence of spare receptors the maximum effect of an agonist drug is achieved with fewer than 100% of the receptors being occupied. To determine the presence of spare receptors, scientists often compare the concentration of the drug needed to produce 50% of the maximum effect (EC50) with the concentration of the drug needed to occupy 50% of the receptors (Kd). If the...
4.6K
Line Loss
545
The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
545
Reducing Line Loss
390
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
390
Pain
1.4K
Pain serves as a critical warning signal that alerts the body to potential or actual harm. When mechanical pressure on the skin is intense, such as from a sharp pinch, the sensation transitions from touch to pain. Similarly, extreme temperatures, like a hot pot handle, convert the sensation of heat into pain. Pain can also result from overstimulation of other senses, such as blinding light, loud noise, or the intense heat from habañero peppers. This ability to sense pain is essential for...
1.4K
Energy Losses in Transformers
1.3K
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
1.3K
Major Losses in Pipes
2.0K
When a fluid flows through a pipe, it experiences energy losses due to frictional resistance along the pipe walls, known as major losses. These energy losses result in a pressure drop, which varies based on the flow conditions — whether laminar or turbulent — and the specific physical properties of the fluid and pipe.
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
2.0K

