A novel rProtein A chromatographic media for enhancing cleaning-in-place performance
Lan Zhao1, Wei Wei2, Yongdong Huang1
1State Key Laboratory of Biochemical Engineering, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, China.
Abstract:
Protein A chromatography has been a popular method for purification of therapeutic monoclonal antibodies (mAb). Protein A chromatographic media using alkali-resistant rProtein A ligands from site-directed coupling method have been pursued for both high dynamic capacities and excellent stabilities. However, the mechanism of rProtein A leaking under cleaning-in-place (CIP) conditions is not very clear and difficulties have been commonly encountered when improving the media's chromatographic performance. We investigated the chromatographic performance of site-directed coupled rProtein A chromatographic media during CIP procedure. Trace amount of ligands leaked during the chromatographic media's incubation in 0.5 M NaOH was detected, explaining for the decline of chromatographic media's CIP performance. Decrease of rProtein A's concentration in 0.5 M NaOH was consistent with chromatographic media's binding capacity. A novel rProtein A chromatographic media were prepared by site-directed coupling a newly-constructed alkali-resistant rProtein A to highly cross-linked agarose-based matrix. The media had a dynamic binding capacity of 63.2 mg hIgG/mL higher than 48.1 mg hIgG/mL of the commercial one, and the CIP performance was improved greatly with the remained dynamic binding capacity increased from 86% to 95% of the initial value after 40 CIP cycles.
Related Concept Videos
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Chromatographic Methods: Terminology
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Microbial Growth Media