Quantifying the utilization of medical devices necessary to detect postmarket safety differences: A case study of
Jonathan Bates1, Craig S Parzynski1, Sanket S Dhruva1,2,3
1Center for Outcomes Research and Evaluation, Yale-New Haven Health System, New Haven, CT, USA.
Purpose:
To estimate medical device utilization needed to detect safety differences among implantable cardioverter defibrillators (ICDs) generator models and compare these estimates to utilization in practice.
Methods:
We conducted repeated sample size estimates to calculate the medical device utilization needed, systematically varying device-specific safety event rate ratios and significance levels while maintaining 80% power, testing 3 average adverse event rates (3.9, 6.1, and 12.6 events per 100 person-years) estimated from the American College of Cardiology's 2006 to 2010 National Cardiovascular Data Registry of ICDs. We then compared with actual medical device utilization.
Results:
At significance level 0.05 and 80% power, 34% or fewer ICD models accrued sufficient utilization in practice to detect safety differences for rate ratios <1.15 and an average event rate of 12.6 events per 100 person-years. For average event rates of 3.9 and 12.6 events per 100 person-years, 30% and 50% of ICD models, respectively, accrued sufficient utilization for a rate ratio of 1.25, whereas 52% and 67% for a rate ratio of 1.50. Because actual ICD utilization was not uniformly distributed across ICD models, the proportion of individuals receiving any ICD that accrued sufficient utilization in practice was 0% to 21%, 32% to 70%, and 67% to 84% for rate ratios of 1.05, 1.15, and 1.25, respectively, for the range of 3 average adverse event rates.
Conclusions:
Small safety differences among ICD generator models are unlikely to be detected through routine surveillance given current ICD utilization in practice, but large safety differences can be detected for most patients at anticipated average adverse event rates.
More Related Videos
04:35Author Spotlight: Innovative Methodology for Implanting and Securing Neural Probes in the Rodent Spinal Cord
Published on: July 12, 2024
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
Related Concept Videos
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Survey Safety
Quantifying Work
Inhaled Medications
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
Identifying Statistically Significant Differences: The F-Test