Related Experiment Video
Updated: Feb 9, 2026

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Joint reconstruction of rest/stress myocardial perfusion SPECT
X Lai1,2, Y Petibon1,2, G El Fakhri1,2
1Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02114, United States of America.
Abstract:
Myocardial perfusion imaging (MPI) using rest/stress single photon emission computed tomography (SPECT) allows non-invasive assessment of reversible cardiac perfusion defects. Conventionally, reversible defects are identified using a difference image, called reversible map, obtained by subtracting the stress image from the rest image after registration and normalization of the two images. The identification of reversible defects using the conventional subtraction method is however limited by noise. We propose to jointly reconstruct rest and stress projection data to directly obtain the reversible map in a single reconstruction framework to improve the detectability of reversible defects. To evaluate the performance of the proposed method, we performed phantom studies to mimic reversible defects with different levels of severity and doses. As compared to the conventional subtraction method, the joint method yielded reversible maps with much lower noise and improved defect detectability. At a normal clinical dose level, the joint method improved the signal to noise ratio (SNR) of defect contrast in reversible maps from 13.2 to 66.4, 9.7 to 35.0, 6.1 to 13.2, and 3.1 to 6.5, for defect to normal myocardium concentration ratios of 0%, 25%, 50%, and 75%, respectively. The SNRs obtained using the joint method were improved from 6.1 to 13.2, 3.9 to 9.4, 3.0 to 8.0, and 2.1 to 7.1, for 100%, 75%, 50%, and 25% of the normal clinical dose as compared to the conventional subtraction method. To access clinical feasibility, we applied the joint method to a rest/stress SPECT MPI patient study. The joint method yielded a reversible map with much lower noise, translating into a much higher defect detectability as compared to the conventional subtraction method. Our results indicate that the joint method has the potential to improve radiologists' performance for assessing defects in rest/stress SPECT MPI. In addition, the joint method can be used to reduce dose or imaging time.
Related Concept Videos
The Resting Membrane Potential
Resting Membrane Potential
The Inside of a Neuron is More Negative
The membrane potential of a cell can be measured by inserting a microelectrode into a cell and comparing the charge to a reference electrode in the extracellular fluid. The...
Resting Potential Decay
At rest, the K+ is the main ion that moves across the membrane...
Structural Joints: Synovial Joints
Structural Joints: Fibrous Joints
Suture
All the bones of the skull, except for the mandible, are joined to each other by a fibrous joint called a suture. The fibrous connective tissue found at a suture strongly unites the adjacent skull bones and thus helps to protect the brain and form the face. In...
Structural Joints: Cartilaginous Joints
There are two types of cartilaginous joints:
Synchondrosis
A synchondrosis ("joined by cartilage") is a cartilaginous joint where bones are connected by hyaline cartilage. Synchondrosis may be temporary...