Related Experiment Video
Updated: Feb 9, 2026

Optimized Protocol for the Extraction of Proteins from the Human Mitral Valve
Published on: June 14, 2017
Mitral valve posterior leaflet reconstruction using extracellular matrix: an acute porcine study
Marcell J Tjørnild1,2, Søren N Skov1,2, Karen B Poulsen1,2
1Department of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark.
This study demonstrates successful mitral valve reconstruction using a small intestinal submucosal extracellular matrix sheet in a porcine model. The reconstructed valve showed no signs of regurgitation or stenosis, indicating functional restoration.
Area of Science:
- Cardiovascular Surgery
- Biomaterials Science
- Regenerative Medicine
Background:
- Mitral valve disease remains a significant clinical challenge, necessitating advanced reconstructive techniques.
- Small intestinal submucosal extracellular matrix (SIS-ECM) sheets offer a promising biomaterial for tissue engineering and repair.
Purpose of the Study:
- To evaluate the feasibility and efficacy of reconstructing the mitral valve posterior leaflet and subvalvular apparatus using a 2-ply SIS-ECM sheet.
- To characterize the functional and geometric outcomes of this novel reconstruction method in an acute porcine model.
Main Methods:
- Mitral valve posterior leaflet and subvalvular reconstruction was performed in an acute porcine model (n=7).
- Hemodynamic assessment using pressure catheter measurements evaluated mitral regurgitation, stenosis, and systolic anterior motion.
- Echocardiography and sonomicrometry were employed to assess leaflet mobility, geometry, and annular dimensions.
Main Results:
- The reconstructed mitral valve demonstrated full functionality, with no significant regurgitation (11 ± 2 mmHg vs 12 ± 2 mmHg) or stenosis (4.1 ± 2.3 mmHg vs 4.8 ± 2.3 mmHg).
- Echocardiography revealed increased coaptation length (8.7 ± 2.3 mm vs 6.0 ± 0.6 mm) and an atrial bend of the posterior leaflet.
- A ballooning effect of the SIS-ECM patch was observed at the posterior annular segment.
Conclusions:
- Reconstruction of the mitral valve posterior leaflet and subvalvular apparatus using a 2-ply SIS-ECM sheet is feasible in an acute porcine model.
- The reconstructed valve exhibited normal function without stenosis or regurgitation.
- The observed ballooning effect may indicate altered leaflet stress distribution, warranting further investigation.
More Related Videos
Related Concept Videos
The Extracellular Matrix
The Extracellular Matrix
In order to maintain tissue organization, many animal cells are surrounded by structural molecules that make up the extracellular matrix (ECM). Together, the molecules in the ECM maintain the structural integrity of tissue as well as the remarkable specific properties of certain tissues.
Composition of the Extracellular Matrix
The extracellular matrix (ECM) is commonly composed of ground substance, a gel-like fluid, fibrous components, and many structurally and functionally diverse...
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Extracellular Matrix
Mitral Valve Prolapse III: Nursing Management

