Related Experiment Video
Updated: Feb 9, 2026

Intraoperative Ultrasound in Spinal Surgery
Published on: August 17, 2022
Feasibility of A-mode ultrasound based intraoperative registration in computer-aided orthopedic surgery: A simulation
Kenan Niu1, Jasper Homminga1, Victor I Sluiter1
1Laboratory of Biomechanical Engineering, Faculty of Engineering Technology, MIRA Institute, University of Twente, Enschede, the Netherlands.
Purpose:
A fast and accurate intraoperative registration method is important for Computer-Aided Orthopedic Surgery (CAOS). A-mode ultrasound (US) is able to acquire bone surface data in a non-invasive manner. To utilize A-mode US in CAOS, a suitable registration algorithm is necessary with a small number of registration points and the presence of measurement errors. Therefore, we investigated the effects of (1) the number of registration points and (2) the Ultrasound Point Localization Error (UPLE) on the overall registration accuracy.
Methods:
We proposed a new registration method (ICP-PS), including the Iterative Closest Points (ICP) algorithm and a Perturbation Search algorithm. This method enables to avoid getting stuck in the local minimum of ICP iterations and to find the adjacent global minimum. This registration method was subsequently validated in a numerical simulation and a cadaveric experiment using a 3D-tracked A-mode US system.
Results:
The results showed that ICP-PS outperformed the standard ICP algorithm. The registration accuracy improved with the addition of ultrasound registration points. In the numerical simulation, for 25 sample points with zero UPLE, the averaged registration error of ICP-PS reached 0.25 mm, while 1.71 mm for ICP, decreasing by 85.38%. In the cadaver experiment, using 25 registration points, ICP-PS achieved an RMSE of 2.81 mm relative to 5.84 mm for the ICP, decreasing by 51.88%.
Conclusions:
The simulation approach provided a well-defined framework for estimating the necessary number of ultrasound registration points and acceptable level of UPLE for a given required level of accuracy for intraoperative registration in CAOS. ICP-PS method is suitable for A-mode US based intraoperative registration. This study would facilitate the application of A-mode US probe in registering the point cloud to a known shape model, which also has the potential for accurately estimating bone position and orientation for skeletal motion tracking and surgical navigation.
More Related Videos
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
05:42Orthopedic Robot-Assisted Femoral Neck System in the Treatment of Femoral Neck Fracture
Published on: March 3, 2023
Related Concept Videos
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Modes of Standing Waves - I
Modes of Standing Waves: II
For a tube open at one end and closed at the other filled with air, the modes are such that there is always an antinode at the open end and a node at the closed end....
MOSFET: Enhancement Mode
In their basic form, enhancement-mode MOSFETs are typically non-conductive when the gate-source voltage (Vgs) is zero. This default 'off' state means no...
Modes of Operations of BJT
Active Mode: The most common mode for amplification, the active mode features a forward-biased emitter-base junction and a reverse-biased base-collector junction. This setup enables electrons to be injected from the emitter to the base while blocking the majority carriers at the collector. The...