Related Experiment Video
Updated: Feb 9, 2026

Rare Event Detection Using Error-corrected DNA and RNA Sequencing
Published on: August 3, 2018
Detecting Rare AID-Induced Mutations in B-Lineage Oncogenes from High-Throughput Sequencing Data Using the Detection
Ophélie Alyssa Martin1,2,3,4, Armand Garot1,2,3,4, Sandrine Le Noir1,2,3,4
1CNRS, Contrôle de la Réponse Immune B et des Lymphoproliférations, UMR 7276, F-87000 Limoges, France.
Abstract:
In B-lineage cells, the cytidine deaminase AID not only generates somatic mutations to variable regions of Ig genes but also inflicts, at a lower frequency, mutations to several non-Ig genes named AID off-targets, which include proto-oncogenes. High-throughput sequencing should be in principle the method of choice to detect and document these rare nucleotide substitutions. So far, high-throughput sequencing-based methods are impaired by a global sequencing error rate that usually covers the real mutation rate of AID off-target genes in activated B cells. We demonstrate the validity of a per-base background subtraction method called detection of minor variants by error correction (DeMinEr), which uses deep sequencing data from mutated and nonmutated samples to correct the substitution frequency at each nucleotide position along the sequenced region. Our DeMinEr method identifies somatic mutations at a frequency down to 0.02% at any nucleotide position within two off-target genes: Cd83 and Bcl6 Biological models and control conditions such as AID- and UNG-deficient mice validate the specificity and the sensitivity of our method. The high resolution and robustness of DeMinEr enable us to document fine effects such as age-dependent accumulation of mutations in these oncogenes in the mouse.
Related Concept Videos
Detection of Gross Error: The Q Test
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
NMR Spectrometers: Resolution and Error Correction
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Mutations
Spontaneous and Induced Mutations

