Second-order modeling for the pulmonary oxygen uptake on-kinetics: a comprehensive solution for overshooting and
Luis A P de Lima1,2, Maxime Raison1, Sofiane Achiche1
1Mechanical Engineering Department, Polytechnique Montréal, Quebec, Canada.
Abstract:
The human oxygen uptake (V̇o2) response to step-like increases in work rate is currently modeled by a First Order System Multi-Exponential (FOME) arrangement. Because of their first-order nature, none of FOME model's exponentials is able to model an overshoot in the oxygen uptake kinetics (OV̇o2K). Nevertheless, OV̇o2K phenomena are observed in the fundamental component of trained individuals' step responses. We hypothesized that a Mixed Multi-Exponential (MiME) model, where the fundamental component is modeled with a second- instead of a first-order system, would present a better overall performance than that of the traditional FOME model in fitting V̇o2 on-kinetics at all work rates, either presenting or not OV̇o2K. Fourteen well-trained male cyclists performed three step on-transitions at each of three work rates below their individual lactate thresholds' work rate (WRLT), and two step on-transitions at each of two exercise intensities above WRLT. Averaged responses for each work rate were fitted with MiME and FOME models. Root mean standard errors were used for comparisons between fitting performances. Additionally, a methodology for detecting and quantifying OV̇o2K phenomena is proposed. Second order solutions performed better (P < 0.000) than the first-order exponential when the OV̇o2K was present, and did not differ statistically (P = 0.973) in its absence. OV̇o2K occurrences were observed below and, for the first time, above WRLT (88 and 7%, respectively). We concluded that the MiME model is more adequate and comprehensive than the FOME model in explaining V̇o2 step on-transient responses, considering cases with or without OV̇o2K altogether.NEW & NOTEWORTHY To our knowledge, this is the first study applying second-order system equations to model V̇o2 on-kinetics, which is useful for both mathematical representation and physiological understanding of the overshoot phenomenon manifesting in the fundamental components of some step responses. Moreover, an objective methodology for detecting and quantifying this overshoot that considers data from the whole response is proposed. Finally, this is the first work detecting overshoot occurrences outside the moderate domain of exercise.
More Related Videos
Related Concept Videos
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Kinetic Energy
Solution Formation
This selective...
Enzyme Kinetics
Scientists typically study enzyme kinetics with a fixed amount of enzyme in the controlled environment of a test tube. When more reactant, or substrate, is...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Kinetic Molecular Theory: Molecular Velocities, Temperature, and Kinetic Energy


