Related Experiment Video
Updated: Feb 9, 2026

Virtual Prism Adaptation Therapy: Protocol for Validation in Healthy Adults
Published on: February 12, 2020
Phantom Validation of Spectral Detector Computed Tomography-Derived Virtual Monoenergetic, Virtual Noncontrast, and
Lakshmi Ananthakrishnan1, Xinhui Duan, Prabhakar Rajiah
1From the UT Southwestern Medical Center, Dallas, TX.
Purpose:
Spectral detector computed tomography (SDCT) is a new CT technology that uses a dual-layer detector to perform energy separation. We aim to assess 3 clinical concepts using a phantom model: noise profile across the virtual monoenergetic (VME) spectrum, accuracy of iodine quantification, and virtual noncontrast (VNC) reconstructions' ability to remove iodine contribution to attenuation.
Methods:
Six vials containing varying concentrations of iodinated contrast (0-6 mg/mL) diluted in water were placed in a water bath and scanned on an SDCT scanner. Virtual monoenergetic (40-200 keV at 10-keV increments), iodine-no-water, and VNC reconstructions were created. Attenuation (in Hounsfield units [HU]), VME noise at each energy level, CT-derived iodine concentration, and VNC attenuation were recorded.
Results:
Virtual monoenergetic noise was improved at all energies compared with conventional images (conventional, 9.8-11.2; VME, 7.5-9.5). Noise profile showed a slightly higher image noise at 40 keV, but was otherwise relatively flat across the energy spectrum. On iodine-no-water reconstructions, measured varied from actual iodine concentration by ±0.1 mg/mL (SD, 0.16-0.36). Virtual noncontrast attenuation was within 5 HU of water attenuation at all iodine concentrations.
Conclusion:
Reconstructions of SDCT show lower VME image noise, accurate iodine quantification, and VNC attenuation values within 5 HU of expected in a phantom model.
Related Concept Videos
Virtual Work
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...
Principle of Virtual Work: Problem Solving
To apply the principle of virtual work,...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Virtual Work for a System of Connected Rigid Bodies
Next,...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...

