Related Experiment Video
Updated: Feb 9, 2026

Author Spotlight: A Reproductive Hysteroscopy Approach for Complete Endometrial Polyp Removal and Enhanced Endometrial Receptivity
Published on: August 2, 2024
Magnetic Resonance Imaging Features of Endometrial Polyps: Frequency of Occurrence and Interobserver Reliability
Patricia Balcacer1, Kirsten A Cooper, Steffen Huber
1From the Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, CT.
Objective:
This study aimed to evaluate magnetic resonance imaging (MRI) features and interobserver agreement of endometrial polyps.
Methods:
After institutional review board approval, our database was searched for women older than 18 years who underwent MRI pelvis and pelvic surgical intervention from 2012 to 2016. Seventy-two patients with polyps and 75 controls composed the study cohort. Two radiologists evaluated the MRIs retrospectively for polyps. Polyp characteristics and enhancement were assessed.
Results:
Sensitivity and specificity of readers 1 and 2 were 59.7% and 88.0%, and 44.4 and 96.0%, respectively. There was moderate agreement for presence of polyps (κ = 0.556, P ≤ 0001), T2 fibrous core, and intratumoral cysts, with slight agreement for T2 signal and enhancement. Polyp size moderately correlated with pathology (κ = 0.465 [P = 0.025] for reader 1, κ = 0.562 [P = 0.029] for reader 2). The most common enhancement was same as myometrium.
Conclusion:
Magnetic resonance imaging is moderately sensitive for detecting endometrial polyps, demonstrating features that are not sensitive but can be specific, with moderate interobserver agreement.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Atomic Nuclei: Magnetic Resonance
Reliability and Validity
Nuclear Magnetic Resonance (NMR): Overview
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
Resonance