A Computed Tomography Study of the C7 Vertebra Screws Fixation in Children
Junhao Liu1, Wei Ji, Zucheng Huang
1Department of Spinal Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, China.
Study Design:
Retrospective analysis of computed tomographic images of 92 normal pediatric cervical vertebrae.
Objective:
The aim of this study was to ascertain the feasibility of the pedicle, intralaminar, and lateral mass screws fixation in children.
Summary Of Background Data:
Fixation techniques of C7 vertebrae are technically challenging in the pediatric population. Although the techniques offer alternatives to screws placement at C7 spine in adult, there is no consensus to apply these screws in children.
Methods:
A total of 92 patients (59 males and 33 females) from 3- to 16-year old divided into three groups (group 1, 1-6 years; group2, 7-10 years; group 3, 11-16 years) were included. Measurements were taken through computed tomography (CT) imaging without evidence of spinal trauma. Length, width, and angle of lamina and pedicle were measured, and lateral mass length was also assessed.
Results:
There was no statistical difference between the left and right sides, as well as the sexes. In 1 to 6 years' age group, 83.3% of the laminas and 87.5% of the pedicles measured have thicknesses of >3.5 mm. In 7 to 10 years' age group, 84.0% of the laminas and all the pedicles observed have thicknesses of >3.5 mm. In 11 to 16 years' age group, 88.4% of the laminas and 97.7% of the pedicles measured have thicknesses of >3.5 mm. Most of the spinolaminar angles were between 42.5° and 56°. There are three cases (3.3%) having lateral mass length >12 mm.
Conclusion:
It is feasible to insert a screw (Ø 3.5 mm) in C7 lamina in children, and the intralaminar screw fixation is a safe and reliable technique. Around 49°, the spinolaminar angle with axial position, can be used as reference for placing screws in the C7 lamina. Preoperative CT scan will help surgeons to insert the laminar screw safely and accurately.
Level Of Evidence:
N/A.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
General Structure of a Vertebra
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...