Related Experiment Video
Updated: Feb 9, 2026

14:49
Self-reporting Scaffolds for 3-Dimensional Cell Culture
Published on: November 7, 2013
13.7K
Correction: Scaffold-free three-dimensional cell culturing using magnetic levitation
Esra Türker1, Nida Demirçak, Ahu Arslan-Yildiz
1Department of Bioengineering, Izmir Institute of Technology (IZTECH), 35430, Izmir, Turkey. ahuarslan@iyte.edu.tr.
Biomaterials Science
|June 15, 2018
Summary
This correction clarifies details for scaffold-free 3D cell culture using magnetic levitation. It ensures accurate understanding of the biomaterials science techniques presented in the original study.
Area of Science:
- Biomaterials Science
- Tissue Engineering
- Cell Biology
Background:
- Three-dimensional (3D) cell culture models are crucial for mimicking in vivo environments.
- Scaffold-free methods offer advantages by avoiding material-related artifacts.
- Magnetic levitation provides a unique approach for 3D spheroid formation.
Purpose of the Study:
- To correct specific details within the original publication on scaffold-free 3D cell culturing.
- To ensure the reproducibility and accuracy of the magnetic levitation technique for spheroid generation.
- To provide updated information for researchers in biomaterials and regenerative medicine.
Main Methods:
- Correction pertains to the methodology of scaffold-free spheroid formation using magnetic levitation.
- Details regarding magnetic bead concentration and cell seeding are clarified.
- Specific parameters for achieving stable levitation and spheroid integrity are addressed.
Main Results:
- The correction ensures that the reported results accurately reflect the experimental conditions.
- Clarifications enhance the understanding of cell-cell interactions within the levitated spheroids.
- The corrected information supports the efficacy of magnetic levitation for generating uniform 3D cell constructs.
Conclusions:
- The corrected information reinforces the utility of magnetic levitation for scaffold-free 3D cell culture.
- Accurate methodology is vital for advancing tissue engineering and drug screening applications.
- This correction ensures the integrity of the scientific record for future research.
Related Concept Videos
Distance Corrections
297
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
297
Power Factor Correction
547
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
547
Dimensional Analysis
65.0K
Dimensional analysis, also known as the factor label method, is a versatile approach for mathematical operations. The main principle behind this approach is: the units of quantities must be subjected to the same mathematical operations as their associated numbers. This method can be applied to computations ranging from simple unit conversions to more complex and multi-step calculations involving several different quantities and their units.
Conversion Factors and Dimensional Analysis
The unit...
Conversion Factors and Dimensional Analysis
The unit...
65.0K
Dimensional Analysis
682
Dimensional analysis is a valuable technique in fluid mechanics for simplifying complex problems by reducing them into dimensionless groups. These groups capture the essential relationships between the variables involved, allowing researchers and engineers to analyze fluid flow without dealing with each variable individually. This approach reduces the number of independent variables, allowing for easier analysis and better understanding of physical phenomena.
In fluid mechanics, dimensional...
In fluid mechanics, dimensional...
682
NMR Spectrometers: Resolution and Error Correction
1.1K
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.1K
Colors and Magnetism
14.1K
Color in Coordination Complexes
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
14.1K