Preferred sampler inlet configurations for collection of aerosolized nano-scale materials
John Jankovic1, Tracy L Zontek2, Megan Moore3
1a Integrated Research Operations , Oak Ridge National Laboratory, Center for Nanophase Materials Sciences , Oak Ridge , TN , USA.
Background:
Due to the lack of standard industrial hygiene sampling protocols for collection of nano-scale materials, sampling inlet device selection is left to individual researchers and professionals.
Objective:
The objective of this study was to compare nano-scale aspiration efficiency for common inlet configurations with that of an open-ended sampler tube that is a commonly used inlet for direct reading instruments such as a condensation particle counter.
Methods:
A polydisperse aerosol was generated using an electric motor as the aerosol source. Typical aerosols generated by this method produced particles with geometric mean mobility diameters of approximately 30 nm with geometric standard deviations of approximately 2. Comparison of raw particle counts in size ranges measured with a scanning mobility particle analyzer was made by determining the fractional difference between the selected inlet and that of the open-ended tube.
Results:
Particle size distributions were nearly identical for all inlet types. The same held true for numbers of particles collected with the exception that the needle inlet was highly variable.
Conclusions:
When completing air monitoring for nano-scale materials, inlets on most collection devices (filters, tubing) do not impact aspiration efficiency. This means that it is not necessary to match inlet configurations when using multiple methods to collect and analyze nano-scale materials.
Related Concept Videos
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Electron Configurations
The relative energies of the subshells determine the order in which atomic orbitals are filled (1s, 2s, 2p, 3s, 3p,...
Electron Configuration of Multielectron Atoms
Configurations of BJT
The common base configuration is noted for its high voltage gain, positioning it as an ideal choice for single-stage amplifier circuits, such as microphone pre-amplifiers. A notable...
Stability of Equilibrium Configuration
A stable equilibrium occurs when a system tends to return to its original position when given a small displacement, and the potential energy is at its minimum. An example of a stable equilibrium is when a cantilever beam is fixed at one end and a weight is attached to the other end. If the weight...
pH Scale