[Application of three different methods for estimating of the plasma volume in children]

Yu Zhang1, Lichen Yang1, Xiaobing Liu1

  • 1National Institute for Nutrition and Health, Chinese Center for Disease Control and Prevention;Laboratory of Trace Element Nutrition MoH China, Beijing 100050, China.

Insights

Three methods for estimating children's blood volume show good consistency. Body weight and formula methods are convenient, while bioelectrical impedance analysis (BIA) is best for children with higher body fat.

Area of Science:

  • Pediatric Physiology
  • Body Composition Analysis
  • Clinical Measurement Techniques

Background:

  • Accurate estimation of plasma volume is crucial for pediatric health assessments.
  • Existing methods for blood volume estimation in children vary in accuracy and applicability.
  • Standardization of measurement techniques is needed for reliable clinical data.

Purpose of the Study:

  • To compare the accuracy and consistency of three distinct methods for estimating plasma volume in children.
  • To evaluate the suitability of each method across different body compositions.
  • To identify the most practical and reliable method for pediatric blood volume assessment.

Main Methods:

  • Blood volume was estimated in 57 children (aged 10-12) using three methods: body weight, the Woodhead formula, and bioelectrical impedance analysis (BIA).
  • Statistical analyses, including Passing & Bablok regression, were employed to compare the methods.
  • Children were subgrouped by body fat percentage to assess method performance variations.

Main Results:

  • No significant differences were found between the three methods in overall blood volume estimation (P > 0.05).
  • Regression analysis indicated good linear correlation between methods, with minor variations in residual standard deviation.
  • Differences emerged when analyzing by body fat: body weight yielded the highest estimates, BIA the lowest in overweight/obese children, while normal-weight children showed no significant differences.

Conclusions:

  • The three methods for estimating blood volume in children demonstrate good consistency.
  • Estimations using body weight and the Woodhead formula offer convenience for clinical application.
  • Bioelectrical impedance analysis (BIA) is particularly suitable for children with higher body fat percentages.
Abstract

Related Concept Videos

Applications of the Ideal Gas Law: Molar Mass, Density, and Volume03:43

Applications of the Ideal Gas Law: Molar Mass, Density, and Volume

The volume occupied by one mole of a substance is its molar volume. The ideal gas law, PV = nRT,  suggests that the volume of a given quantity of gas and the number of moles in a given volume of gas vary with changes in pressure and temperature. At standard temperature and pressure, or STP (273.15 K and 1 atm), one mole of an ideal gas (regardless of its identity) has a volume of about 22.4 L — this is referred to as the standard molar volume.
63.5K
What are Estimates?01:06

What are Estimates?

It isn't easy to measure a parameter such as the mean height or the mean weight of a population. So, we draw samples from the population and calculate the mean height or mean weight of the individuals in the sample. This sample data acts as a representative measure of the population parameter. These sample statistics are known as estimates. 
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...
8.8K
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution01:09

One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution

The one-compartment open model is a simplified approach used in pharmacokinetics to understand the distribution and elimination of a drug administered through an intravenous bolus. This model assumes rapid drug dispersal throughout the body and elimination using a first-order process. Key pharmacokinetic parameters, such as the elimination rate constant (k), half-life (t1/2), and the apparent volume of distribution (Vd), can be estimated from this model. The elimination rate is calculated...
897
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation01:24

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation

This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
1.2K
Estimation of k and VD of Aminoglycosides01:20

Estimation of k and VD of Aminoglycosides

Aminoglycosides are a class of antibiotics used to treat various bacterial infections. Clinicians must determine the elimination rate constant (k) and volume of distribution (VD) to optimize therapeutic efficacy and minimize toxicity. The k value represents the rate at which the drug is removed from the body, and the VD reflects the degree to which the drug distributes into body tissues. Accurately estimating these parameters allows healthcare professionals to tailor drug dosing to individual...
250
Constant Volume Calorimetry02:41

Constant Volume Calorimetry

Calorimeters are useful to determine the heat released or absorbed by a chemical reaction. Coffee cup calorimeters are designed to operate at constant (atmospheric) pressure and are convenient to measure heat flow (or enthalpy change) accompanying processes that occur in solution at constant pressure. A different type of calorimeter that operates at constant volume, colloquially known as a bomb calorimeter, is used to measure the energy produced by reactions that yield large amounts of heat and...
30.8K