Objective:
A method for the determination of 5 kinds of phthalate monoesters in urine by solid-phase extraction and gas chromatography-mass spectrometry was developed.
Methods:
After urine enzymatic hydrolysis by β-glucuronidase, the sample was pretreated by SPE. Phthalate monoesters were eluted by boron trifluoridemethanol complex, and determined by gas chromatograph-mass spectrometer with DB-5 ms Phenomenex( 30 m × 0. 25 mm, 0. 25 μm).
Results:
Within the concentration range of25. 0-1000 μg/L, the relationship between peak area and concentration of 5 kinds of phthalate monoesters presented linear relation. The correlation coefficient was 0. 9989-0. 9996, and the determination limit was 10. 0-15. 0 μg/L. The recoveries of phthalate monoesters were in the range of 80. 2%-97. 8% when set at 15. 0, 200 and 500 μg/L concentration levels, and the relative standard deviation was in the range of 4. 2%-10. 2%( n = 6). A total of 81 pregnant women were detected by this method and thedetection rate was 98. 7%.
Conclusion:
This method could be used in the simultaneous determination of 5 kinds of phthalate monoesters.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Mass Spectrometry: Carboxylic Acid, Ester, and Amide Fragmentation
For example, the...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Chemical Stoichiometry and Gases: Using Ideal Gas Law to Determine Moles
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...