Related Experiment Video
Updated: Feb 9, 2026

VirWaTest, A Point-of-Use Method for the Detection of Viruses in Water Samples
Published on: May 11, 2019
[Equivalence test between trial method and reference method of the total coliforms and E. Coli in water]
Liping Wu1, Xiaolu Li1, Congying Liu1
1National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China.
Objective:
To compare the equivalence on detection total coliforms and E. Coli between a new technique with portable sterile culture system and enzyme substrate technique by 51 holes in water.
Methods:
Collected drinking water and source water, then detected total coliforms and E. Coli using the twomethod in three laboratories respectively. Analyzed the experimentalresult according to the ISO 17994∶ 2014 which was dedicated to analyze the equivance of water quality between different microbial detection method.
Results:
The confidence upper limit of the expanded uncertainty of the mean of total coliforms from three laboratories were within the range from 0. 0494 to 0. 0903, andthe range of confidence lower limit were from minus 0. 0713 to minus 0. 0490. The confidence upper limit of the expanded uncertainty of the mean of E. Coli from three laboratories were within the range from 0. 0307 to 0. 0882, while the range of confidence lower limit were from minus 0. 0928 to minus 0. 0381. They were all within the acceptable range which the confidence upper limit was from 0 to 0. 10000, and the confidence lower limit was from minus 0. 10000 to 0.
Conclusion:
The aforementioned method in detecting total coliforms and E. Coli possess the equivalence compared with the classical method, so the portable sterile culture system can be an alternative of method detecting total coliforms and E. Coli in water.
Related Concept Videos
The Scientific Method
Equivalent Capacitance
The following strategies are adopted to calculate...
Equivalent Capacitance
Pharmaceutical Equivalents
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...