Convolutional neural network-based PSO for lung nodule false positive reduction on CT images
Related Experiment Video
Updated: Feb 9, 2026

Vascular Casting of Adult and Early Postnatal Mouse Lungs for Micro-CT Imaging
Published on: June 20, 2020
Giovanni Lucca França da Silva1, Thales Levi Azevedo Valente2, Aristófanes Corrêa Silva1
1Federal University of Maranhão - UFMA, Applied Computing Group - NCA Av. dos Portugueses, SN, Bacanga, São Luís, MA 65085-580, Brazil.
Background And Objective:
Detection of lung nodules is critical in CAD systems; this is because of their similar contrast with other structures and low density, which result in the generation of numerous false positives (FPs). Therefore, this study proposes a methodology to reduce the FP number using a deep learning technique in conjunction with an evolutionary technique.
Method:
The particle swarm optimization (PSO) algorithm was used to optimize the network hyperparameters in the convolutional neural network (CNN) in order to enhance the network performance and eliminate the requirement of manual search.
Results:
The methodology was tested on computed tomography (CT) scans from the Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI) with the highest accuracy of 97.62%, sensitivity of 92.20%, specificity of 98.64%, and area under the receiver operating characteristic (ROC) curve of 0.955.
Conclusion:
The results demonstrate the high performance-potential of the PSO algorithm in the identification of optimal CNN hyperparameters for lung nodule candidate classification into nodules and non-nodules, increasing the sensitivity rates in the FP reduction step of CAD systems.
Related Concept Videos
Reactions at the Benzylic Position: Oxidation and Reduction
Convolution Properties II
The width property indicates that if the durations of input signals are T1 and T2, then the width of the output response equals the sum of both durations, irrespective of the shapes of the two functions. For instance, convolving two rectangular pulses with durations of 2 seconds and 1 second results in a function with a width of 3 seconds.
The area property asserts that the area under the...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
False Memories
One primary source of false memories is misattribution, where individuals incorrectly associate external information...
Convolution Properties I
The commutative property reveals that the input and the impulse response of an LTI (Linear Time-Invariant) system can be interchanged without affecting the output:

