Zonally Magnified Oblique Multislice and Non-Zonally Magnified Oblique Multislice DWI of the Cervical Spinal Cord
M Alizadeh1,2, M M Poplawski1, J Fisher1
1From the Department of Radiology (M.A., M.M.P., J.F., R.J.T.G., A.D., F.B.M., A.E.F.), Jefferson Integrated Magnetic Resonance Imaging Center.
Background And Purpose:
The zonally magnified oblique multislice EPI (ZOOM-EPI) diffusion-weighted sequence has been visually shown to provide superior MR diffusion image quality compared with the full-FOV single-shot EPI sequence (non-ZOOM-EPI) in the adult cervical spinal cord. The purpose of this study was to examine the diffusion tensor imaging indices in the normal human cervical spinal cord between ZOOMED and non-ZOOMED DTI acquisitions and determine whether DTI values are comparable between direct and indirect age-matched groups.
Materials And Methods:
Fifty-four subjects 23-58 years of age (9 direct age-matched and 45 indirect age-matched) were scanned using a 1.5T scanner. Diffusion tensor indices including fractional anisotropy, mean diffusivity, axial diffusivity, and radial diffusivity were generated from the DTI dataset. These DTI values were calculated for both ZOOM and non-ZOOM acquisitions and compared at each intervertebral disc level. The variability of the DTI values for ZOOM and non-ZOOM sequences was measured using a coefficient of variation within direct and indirect age-matched controls.
Results:
The mean diffusivity, axial diffusivity, and radial diffusivity values obtained along the cervical spinal cord in the age-matched controls showed a significant decrease using the ZOOM sequence (P = .05, P = .002, and P < .001). Mean fractional anisotropy showed a significant increase (P = .04) using the ZOOM sequence. The indirect age-matched controls showed a statistically significant increase in fractional anisotropy (P = .03) and a decrease in mean diffusivity (P = .002), axial diffusivity (P < .001), and radial diffusivity (P = .002) using the ZOOM sequence. Less variability has been shown in DTI using the ZOOM sequence compared with the non-ZOOM sequence in both direct and indirect age groups. The ZOOM sequence exhibited higher SNR (SNRZOOM = 22.84 ± 7.59) compared with the non-ZOOM sequence (SNRnon-ZOOM = 19.7 ± 7.05). However, when we used a 2-tailed t test assuming unequal variances, the ZOOM sequence did not demonstrate a statistically significant increase.
Conclusions:
ZOOM DTI acquisition methods provide superior image quality and precision over non-ZOOM techniques and are recommended over conventional full-FOV single-shot EPI DTI for clinical applications in cervical spinal cord imaging.
Related Concept Videos
Stress on an Oblique Plane
Spinal Cord
The Spinal Cord
Spinal Cord: Information Processing
Sensory Information Processing
Sensory information processing begins at the sensory receptors located in the skin and other tissues, which detect somatic sensory stimuli such as touch, temperature, or pain. These receptors function as catalysts, initiating...
Spinal Cord: Gross Anatomy
Spinal Cord: Cross-sectional Anatomy
Gray Matter and its Components
Central to the gray matter is...