Related Experiment Video
Updated: Feb 9, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
A rapid, computational approach for assessing interfraction esophageal motion for use in stereotactic body radiation
Michael L Cardenas1, Thomas R Mazur1, Christina I Tsien1
1Washington University in St. Louis, St. Louis, Missouri.
Purpose:
We present a rapid computational method for quantifying interfraction motion of the esophagus in patients undergoing stereotactic body radiation therapy on a magnetic resonance (MR) guided radiation therapy system.
Methods And Materials:
Patients who underwent stereotactic body radiation therapy had simulation computed tomography (CT) and on-treatment MR scans performed. The esophagus was contoured on each scan. CT contours were transferred to MR volumes via rigid registration. Digital Imaging and Communications in Medicine files containing contour points were exported to MATLAB. In-plane CT and MR contour points were spline interpolated, yielding boundaries with centroid positions, CCT and CMR. MR contour points lying outside of the CT contour were extracted. For each such point, BMR(j), a segment from CCT intersecting BMR(j), was produced; its intersection with the CT contour, BCT(i), was calculated. The length of the segment Sij, between BCT(i) and BMR(j), was found. The orientation θ was calculated from Sij vector components:θ = arctan[(Sij)y / (Sij)x]A set of segments {Sij} was produced for each slice and binned by quadrant with 0° < θ ≤ 90°, 90° < θ ≤ 180°, 180° < θ ≤ 270°, and 270° < θ ≤ 360° for the left anterior, right anterior, right posterior, and left posterior quadrants, respectively. Slices were binned into upper, middle, and lower esophageal (LE) segments.
Results:
Seven patients, each having 3 MR scans, were evaluated, yielding 1629 axial slices and 84,716 measurements. The LE segment exhibited the greatest magnitude of motion. The mean LE measurements in the left anterior, left posterior, right anterior, and right posterior were 5.2 ± 0.07 mm, 6.0 ± 0.09 mm, 4.8 ± 0.08 mm, and 5.1 ± 0.08 mm, respectively. There was considerable interpatient variability.
Conclusions:
The LE segment exhibited the greatest magnitude of mobility compared with the middle and upper esophageal segments. A novel computational method enables personalized, nonuniform esophageal margins to be tailored to individual patients.
Related Concept Videos
Equation of Motion for a Rigid Body
The combined moments generated about the center of mass of the object are equal to the rate of change of the angular momentum of the body. An external force, when applied at a different...
Planar Rigid-Body Motion
Planar motion is typically divided into three distinct categories. The first is rectilinear translation, demonstrated by a subway train that moves along...
Biological Effects of Radiation
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...

