Related Experiment Video
Updated: Feb 9, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Single Photon Emission Computed Tomography without and with Hybrid Computed Tomography in Mandibular Condylar
Objective:
Bone scintigraphy (BS) has been the mainstay in evaluating patients with mandibular condylar hyperplasia (CH). Both planar BS and single photon emission computed tomography (SPECT) have been used to determine cessation of condylar hyperactivity before corrective surgery. The present study aimed to examine the utility of the relatively new single photon emission computed tomography/computed tomography (SPECT/CT) technique for evaluation of CH.
Material And Method:
Sixty-one mandibular Tc-99m methylene diphosphonate bone SPECT/CT studies were reviewed. Images were analyzed without and with fusion with anatomical CT. Condylar uptake were quantified and differences in uptake between the right and left condyles were determined by both maximum uptake and average uptake in the region of interes (ROI). Differences exceeding 10 percentage points indicated condylar hyperactivity.
Results:
SPECT and SPECT/CT showed positivity in 34 and 31 examinations, respectively. Agreement between the two modalities was high, but was not perfect. SPECT was found to be more reproducible than SPECT/CT. Quantification using maximum ROI counts was more reproducible than using average ROI counts.
Conclusion:
No evidence was found to indicate superiority of SPECT/CT over simple SPECT for evaluation of condylar hyperactivity in CH, as demonstrated by the lower intra-modality reproducibility and a trend towards lower sensitivity for detection of hyperactive condyles. Utilization of SPECT alone would further benefit in terms of reduction of patient radiation exposure which is a concern, especially in younger patients such as those with CH. When using quantification, maximum ROI counts should be used over average ROI counts.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
12:24Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...