Optimized microfiber-based third-harmonic generation with adaptive control of phase mismatch
Related Experiment Video
Updated: Feb 9, 2026

09:23
Harmonic Nanoparticles for Regenerative Research
Published on: May 1, 2014
12.1K
Optics Letters
|June 16, 2018
Abstract:
An effective approach is presented to improve intermodal third-harmonic generation in microfibers. It is demonstrated that structure-independent incident pump power could be utilized, via its effect on nonlinear phase modulations, to compensate for the phase mismatch caused by diameter deviation. The output harmonic of a fabricated microfiber can be optimized adaptively; thus, efficient third-harmonic generation with efficiency reaching several percent could realistically be achieved.
Related Concept Videos
Mismatch Repair
43.7K
Overview
43.7K
Mismatch Repair
6.6K
Organisms are capable of detecting and fixing nucleotide mismatches that occur during DNA replication. This sophisticated process requires identifying the new strand and replacing the erroneous bases with correct nucleotides. Mismatch repair is coordinated by many proteins in both prokaryotes and eukaryotes.
The Mutator Protein Family Plays a Key Role in DNA Mismatch Repair
The human genome has more than 3 billion base pairs of DNA per cell. Prior to cell division, that vast amount of genetic...
The Mutator Protein Family Plays a Key Role in DNA Mismatch Repair
The human genome has more than 3 billion base pairs of DNA per cell. Prior to cell division, that vast amount of genetic...
6.6K
Phase-lead and Phase-lag Controllers
574
Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
574
Generation of Three-Phase Voltage
823
A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
As the rotor...
823
Harmonic Mean
3.8K
The arithmetic mean is usually skewed towards the larger values in the data set. Therefore, to avoid this inherent bias towards smaller values, the harmonic mean is used.
Take the example of the speed of a car, which is the measure of the rate of distance traveled. If the vehicle traverses the same distance back-and-forth, its average speed equals the total distance traveled divided by the total time taken. However, if the car moves with varying speeds, then the arithmetic mean is more skewed...
Take the example of the speed of a car, which is the measure of the rate of distance traveled. If the vehicle traverses the same distance back-and-forth, its average speed equals the total distance traveled divided by the total time taken. However, if the car moves with varying speeds, then the arithmetic mean is more skewed...
3.8K
Generator Voltage Control
670
Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand, use...
670

