1Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Pokfulam, Hong Kong, China; Department of Microbiology, Queen Mary Hospital, Pokfulam, Hong Kong, China; State Key Laboratory for Emerging Infectious Diseases, The University of Hong Kong, Pokfulam, Hong Kong, China; Carol Yu Centre for Infection, The University of Hong Kong, Hong Kong, China; Department of Clinical Microbiology and Infection Control, The University of Hong Kong-Shenzhen Hospital, Shenzhen, China.
Objectives:
Automated point-of-care molecular assays have greatly shortened the turnaround time of respiratory virus testing. One of the major bottlenecks now lies at the specimen collection step, especially in a busy clinical setting. Saliva is a convenient specimen type that can be provided easily by adult patients. This study assessed the diagnostic validity, specimen collection time and cost associated with the use of saliva.
Methods:
This was a prospective diagnostic validity study comparing the detection rate of respiratory viruses between saliva and nasopharyngeal aspirate (NPA) among adult hospitalized patients using Xpert® Xpress Flu/RSV. The cost and time associated with the collection of saliva and nasopharyngeal specimens were also estimated.
Results:
Between July and October 2017, 214 patients were recruited. The overall agreement between saliva and NPA was 93.3% (196/210, κ 0.851, 95% CI 0.776-0.926). There was no significant difference in the detection rate of respiratory viruses between saliva and NPA (32.9% (69/210) versus 35.7% (75/210); p 0.146). The overall sensitivity and specificity were 90.8% (81.9%-96.2%) and 100% (97.3%-100%), respectively, for saliva, and were 96.1% (88.9%-99.2%) and 98.5% (94.7%-99.8%), respectively, for NPA. The time and cost associated with the collection of saliva were 2.26-fold and 2.59-fold lower, respectively, than those of NPA.
Conclusions:
Saliva specimens have high sensitivity and specificity in the detection of respiratory viruses by an automated multiplex Clinical Laboratory Improvement Amendments-waived point-of-care molecular assay when compared with those of NPA. The use of saliva also reduces the time and cost associated with specimen collection.
Related Concept Videos
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...
Urinary Tract Infection III: Diagnostic Studies and Interprofessional Care
Pericarditis II: Clinical Features and Diagnostic Tests
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests