Related Experiment Video
Updated: Feb 8, 2026

Electrolytic Inferior Vena Cava Model EIM of Venous Thrombosis
Published on: July 12, 2011
Three-Dimensional Inferior Vena Cava for Assessing Central Venous Pressure in Patients with Cardiogenic Shock
Raphaëlle Huguet1, Damien Fard1, Thomas d'Humieres1
1UPEC, AP-HP Henri Mondor University Hospital, Creteil, France; INSERM U955, Creteil, France; DHU ATVB, Creteil, France.
Background:
The inferior vena cava (IVC) has a complex three-dimensional (3D) shape, but measurements used to estimate central venous pressure (CVP) remain based on two-dimensional (2D) echocardiographic imaging. The aim of this study was to investigate the accuracy of IVC size and collapsibility index obtained by 3D echocardiography for assessing CVP in patients with cardiogenic shock.
Methods:
Eighty consecutive echocardiographic examinations performed in 33 patients (mean age, 72 ± 15 years; mean left ventricular ejection fraction, 19 ± 10%) admitted for cardiogenic shock were prospectively included. Two-dimensional and 3D images of the IVC were acquired simultaneously with invasive measurement of CVP, both at rest and during a sniff test. IVC diameters, 3D IVC area, and IVC collapsibility index (IVCCI) were assessed. The eccentricity index was computed from 3D data as the ratio of maximum to minimum IVC diameter. A cutoff value of 10 mm Hg for CVP defined patients with euvolemic hemodynamic status.
Results:
At rest, IVC diameter averaged 23 ± 7 mm by 2D imaging and 25 ± 8 × 19 ± 7 mm by 3D imaging. The IVC had an eccentric shape (eccentricity index = 1.3) that increased when CVP was ≤10 mm Hg and during the sniff test (P < .001). IVC measurements by 2D and 3D imaging were correlated with CVP. The best correlation was obtained with IVCCI derived from 2D diameters (R = -0.69) and 3D areas (R = -0.82). Using a cutoff value of 50% for IVCCI, 11 examinations were misclassified by 2D imaging and only one by 3D imaging. Inter- and intraobserver reproducibility for IVC area was 7 ± 6% and 5 ± 3%, respectively.
Conclusions:
In patients with cardiogenic shock, IVCCI from area by 3D echocardiography is reproducible and accurate to evaluate CVP.
Related Concept Videos
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...
Assessing Blood pressure in the Leg
Preparation:
Shock Waves
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high...
The Central Dogma
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...

