Related Experiment Video
Updated: Feb 8, 2026

Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
Priors-guided slice-wise adaptive outlier cleaning for arterial spin labeling perfusion MRI
Yiran Li1, Sudipto Dolui2, Dan-Feng Xie1
1Department of Electrical and Computer Engineering, Temple University, Philadelphia, PA, USA.
Background:
Due to the low signal-to-noise-ratio (SNR) and unavoidable head motions, the pairwise subtraction perfusion signal extraction process in arterial spin labeling (ASL) perfusion MRI can produce extreme outliers.
Comparison With Existing Methods:
We previously proposed an adaptive outlier cleaning (AOC) algorithm for ASL MRI. While it performed well even for clinical ASL data, two issues still exist. One is that if the reference is already dominated by noise, outlier cleaning using low correlation with the mean as a rejection criterion will actually reject the less noisy samples but keep the more noisy ones. The other is that it is sub-optimal to reject the entire outlier volumes without considering the quality of each constituent slices. To address both problems, a prior-guided and slice-wise AOC algorithm was proposed in this study.
New Methods:
The reference of AOC was initiated to be a pseudo cerebral blood flow (CBF) map based on prior knowledge and outlier rejection was performed at each slice. ASL data from the ADNI database (www.adni-info.org) were used to validate the method. Image preprocessing was performed using ASLtbx.
Results:
The proposed method outperformed the original AOC and SCORE in terms of higher SNR and test-retest stability of the resultant CBF maps.
Conclusion:
ASL CBF can be substantially improved using prior-guided and slice-wise outlier rejection. The proposed method will benefit the ever since increasing ASL user community for both clinical and scientific brain research.
More Related Videos
Related Concept Videos
What Are Outliers?
The z score is used to find outliers or unusual values. It should be noted that any values beyond -2 and +2 are...
Outliers and Influential Points
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Quantifying and Rejecting Outliers: The Grubbs Test
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
NMR Spectroscopy: Spin–Spin Coupling