Related Experiment Video
Updated: Feb 8, 2026

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Mechanolytic management of transcatheter aortic valve thrombosis
Ahmad Sharif-Yakan1, Mohamad Aboukoura1, Christoph A Nienaber1,2
1Division of Cardiology, Department of Internal Medicine, University Hospital Rostock, Rostock, Germany.
Abstract:
Data on the incidence, characteristics, and treatment of thrombosis of a transcatheter aortic valve implantation (TAVI) implant are scarce. We report a challenging case of a TAVI thrombosis occurring 6 months after the procedure. Initial anticoagulation using low-molecular-weight heparin followed by thrombolytic therapy failed to both relieve symptoms and alleviate thrombosis. However, the condition of the patient deteriorated rapidly, necessitating the use of balloon valvuloplasty followed by low-dose thrombolysis. The uniqueness of the case can be summarized as follows: (1) first report of balloon valvuloplasty to manage a case of TAVI thrombosis; (2) thrombolytic therapy after balloon valvuloplasty was successful to further reduce gradient from valve thrombosis.