Related Experiment Video
Updated: Feb 8, 2026

Epidural Intracranial Pressure Measurement in Rats Using a Fiber-optic Pressure Transducer
Published on: April 25, 2012
Experimental validation of the CompuFlo® epidural controlled system to identify the epidural space and its clinical
G Capogna1, M Camorcia1, A Coccoluto1
1Department of Anesthesiology, Città di Roma Hospital, Rome, Italy.
Background:
This prospective study was designed to validate the CompuFlo® device and to assess its use in difficult epidural placement.
Methods:
In the first part of the study, 30 parturients requesting labor epidural analgesia were recruited. The block was performed by an expert anesthesiologist, with the Tuohy needle connected to the CompuFlo® device to evaluate the agreement between the anesthesiologist's reported sensation and the variation of pressure recorded by the CompuFlo®. In the second part of the study, 56 consecutive parturients, for whom at least two complete needle reinsertions were made by trainees during epidural placement for labor analgesia, were enrolled. CompuFlo® was used as a rescue tool for the subsequent attempt.
Results:
In all cases epidural analgesia was successful and no complications were noted. There was a good correlation between the operator's feelings and the delta of pressure recorded by the CompuFlo®, for both identification of the ligamentum flavum and of the epidural space (Rho = 0.79; tau = 0.67). In the second part of the study, all the difficult blocks performed with the CompuFlo® were successful after a single attempt. The pressure curves of false loss-of-resistance were significantly different from the true loss-of-resistance (P <0.0001) DISCUSSION: CompuFlo® was validated as a tool to identify the epidural space. It may also assist trainees in successful epidural placement in difficult cases.
Related Concept Videos
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Reliability and Validity
Space Trusses
At the core of a space truss lies the fundamental unit known as the tetrahedron. This structure is composed of six members that form a three-dimensional shape...
State Space Representation
Consider an RLC circuit, a...
Data Validation
Key parameters for method validation include:
Data Validation