Related Experiment Video
Updated: Feb 8, 2026

Establishing a Diaphyseal Femur Fracture Model in Mice
Published on: December 9, 2022
Measurement Reliability in Pediatric Lateral Condyle Fractures of the Humerus
Daniel C Bland1, Andrew T Pennock1,2, Vidyadhar V Upasani1,2
1Pediatric Orthopedics and Scoliosis Center, Rady Children's Hospital.
Background:
Lateral condyle fractures of the distal humerus are the second most common pediatric elbow fracture. A difference of 1 or 2 mm in fracture displacement measurement may change the operative or nonoperative management of a minimally displaced fracture. The goal of this study was to determine the interobserver and intraobserver agreement in the measurements of displacement of lateral condyle fractures of the humerus.
Methods:
A retrospective radiographic review of 60 patients was performed by 3 reviewers. Fracture displacement was measured in millimeters on all radiographic projections and repeated by a single author 1 month later. Intraclass correlation coefficients (ICC) were calculated for intraobserver and interobserver agreement. We then calculated the percentage of measurements that differed by >1 or 2 mm. Analysis was performed on the entire cohort of displaced fractures and again separately for a cohort of minimally displaced fractures (defined as <5 mm).
Results:
The combined ICC for intraobserver reliability across all radiographic projections was 0.96 (range, 0.952 to 0.977), but there was disagreement between a single reviewer's own measurements 17.3% of the time. Within the cohort of fractures displaced <5 mL, this intrarater disagreement (>2 mm) dropped to 4%. Interobserver reliability was also high with an ICC of 0.90 (range, 0.861 to 0.924). Within the minimally displaced cohort (<5 mm), the interrater disagreement was 6.6% when using a 2 mm cutoff and 22.2% when using a 1 mm cutoff.
Conclusions:
Intraobserver and interobserver reliability are high when measuring lateral condyle fractures and the percent of clinical disagreement is low when measuring minimally displaced fractures for which treatment depends on measuring to the millimeter. The internal oblique projection is the most reliable view for measuring lateral condyle fracture displacement, whereas the external oblique view offers little in terms of reliability. This study may be used as a platform for further research, verifying that reliable measurements of lateral humeral condyle fracture displacement can be obtained within 1 to 2 mm from adequate plain films.
Level Of Evidence:
Level III.
Related Concept Videos
Reliability and Validity
Bones of the Upper Limb: Humerus
Lateralization
Distribution Reliability and Automation
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Pharmacokinetics in Pediatric Patients: Drug Excretion

