Proof of Concept Study: Investigating Force Metrics of an Intracorporeal Suturing Knot Task
Justin Wee1, Georges Azzie2, James Drake3
11 Center for Image Guided Innovation and Therapeutic Intervention, The Hospital for Sick Children, University of Toronto , Toronto, Canada .
Background:
Mastering proper force manipulation in minimally invasive surgery can take many hours of practice and training. Improper force control can lead to necrosis, infection, and scarring. A force-sensing skin (FSS) has been developed, which measures forces at the distal end of minimal access surgeries' (MAS) instruments without altering the instrument's structural integrity or the surgical workflow, and acts as a minimally disruptive add-on to any MAS instrument.
Methods:
A proof of concept study was conducted using a FSS-equipped 5 mm straight-tip needle holder. Participants (n = 19: 3 novices, 11 fellows, and 5 staff surgeons) performed one intracorporeal suturing knot task (ISKT). Using participant task video footage, each participant's two puncture forces (each wall of the Penrose drain) and three knot tightening forces were measured. Force metrics from the three expertise groups were compared using analysis of variance (ANOVA) and Tukey's honest significance test with statistical significance assessed at P < .05.
Results:
Preliminary ISKT force metric data showed differences between novices and more experienced fellows and surgeons. Of the five stages of the ISKT evaluated, the first puncture force of the Penrose drain seemed to best reflect the difference in skill among participants. The study demonstrated ISKT knot tightening and puncture force ranges across three expertise levels (novices, surgical fellows, and staff surgeons) of 0.586 to 6.089 newtons (N) and 0.852 to 2.915 N, respectively.
Conclusion:
The investigation of force metrics is important for the implementation of future force feedback systems as it can provide real-time information to surgeons in training and the operating theater.
Related Concept Videos
Social Proof
Self-Concept
Infancy and Emerging Recognition
During infancy, self-concept is virtually nonexistent. Babies do not distinguish themselves as separate entities and often mistake their...
Concepts and Prototypes
The brain organizes this information using concepts, which are mental categories grouping linguistic data,...
Formula Mass and Mole Concepts of Compounds
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
Basic Concept
Length, which measures the distance traveled by an object, is a fundamental concept in engineering mechanics. We use coordinates relative to a reference point to describe the distance. Length not only helps to describe the...