A personalized, Monte Carlo-based method for internal dosimetric evaluation of radiopharmaceuticals in children
Panagiotis Papadimitroulas1, William D Erwin2, Vasiliki Iliadou3
1R&D Department, BET Solutions, 116 Alexandras Ave., Athens, GR-11472, Greece.
Purpose:
Herein, we introduce a methodology for estimating the absorbed dose in organs at risk that is based on specified clinically derived radiopharmaceutical biodistributions and personalized anatomical characteristics.
Methods:
To evaluate the proposed methodology, we used realistic Monte Carlo (MC) simulations and computational pediatric models to calculate a parameter called in this work the "specific absorbed dose rate" (SADR). The SADR is a unique quantitative metric in that it is specific to a particular organ. It is defined as the absorbed dose rate in an organ when the biodistribution of radioactivity over the whole body is considered. Initially, we applied a validation procedure that calculated specific absorbed fractions (SAFs) from mono-energetic photon sources in the range of 10 keV-2 MeV and compared them with previously published data. We calculated the SADRs for five different radiopharmaceuticals (99m Tc-MDP, 123 I-mIBG, 131 I-MIBG, 131 I-NaI, and 153 Sm-EDTMP) based on their biodistributions at four or five different times; the biodistributions were derived from the clinical scintigraphic data of pediatric patients. We used six models representing male and female patients aged 5, 8, and 14 yr to investigate the absorbed dose variability due to anatomical variations. The GATE Monte Carlo toolkit was used to calculate absorbed doses per organ. Finally, we compared the SADR methodology to that of OLINDA/EXM 1.1 using rescaled masses according to the studied models. Four target organs were considered for calculating the absorbed doses.
Results:
The ratios of SAFs calculated with GATE simulations to those based on previously published data were between 0.9 and 2.2 when the liver was used as a source organ. Subsequently, we used GATE to calculate a dataset of SADRs for the six pediatric models. The SADRs for pediatric models whose total body weights ranged from 20 to 40 kg varied up to approximately 90%, whereas those for models of similar body masses varied less than 15%. Finally, we found absorbed dose discrepancies of approximately 10-150% between the SADR methodology and OLINDA for two different radiopharmaceuticals. Absorbed doses from SADRs and from individualized S-values in the same pediatric model differed approximately 1-50%.
Conclusions:
Because pediatric radiopharmaceutical dosimetric estimates demonstrate large variation due to the patient's anatomical characteristics, personalized data should be considered. Using our SADR method in a larger population of phantoms and for a variety of radiopharmaceuticals could enhance the personalization of dosimetry in pediatric nuclear medicine. The proposed methodology provides the advantage of creating time-dependent organ dose rate curves.
More Related Videos
11:29Measuring the Functional Abilities of Children Aged 3-6 Years Old with Observational Methods and Computer Tools
Published on: June 20, 2020
09:57Author Spotlight: Advancing Pediatric Epilepsy Surgery in Children Through Novel Biomarkers and Enhanced Localization
Published on: September 20, 2024
Related Concept Videos
Internal Energy
Internal Energy
Internal Receptors
Self-Evaluation: Self-Enhancement and Self-Verification
International System of Units
Prefixes are used to define both larger and smaller quantities in the SI system. For example, milli, micro, and nano define smaller quantities, while kilo, mega, and giga are used to define...
Personal Identity