Related Experiment Video
Updated: Feb 8, 2026

Novel Triple-Loop Technique for Suturing TFCC Injuries without Transosseous Tunnel
Published on: May 23, 2025
TFCC Injuries: Meta-Analysis and Comparison of Diagnostic Imaging Modalities
Matthew D Treiser1, Kayva Crawford1, Matthew L Iorio1,2
1Division of Plastic and Reconstructive Surgery, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
Abstract:
Background Imaging of the triangular fibrocartilaginous complex (TFCC) remains difficult, as no single imaging modality demonstrates perfect sensitivity and specificity. Purpose This study performs a meta-analysis of multiple previous publications to guide noninvasive imaging selection for the diagnosis of TFCC injuries. Methods A literature search was performed and conducted. Studies were included that compared the diagnostic accuracy of magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA), and computed tomography (CT)/computed tomographic arthrography (CTA) for the evaluation of TFCC injuries. All studies included either arthroscopic or open surgical findings as the "gold standard." A meta-analysis was performed comparing the diagnostic accuracy of MRA, MRI, and CT for the detection of TFCC injuries. Results Initial search returned 2,568 candidate articles. Studies were then reviewed and narrowed yielding a total of 28 independent studies (20 MRI, 9 MRA, 4 CT/CTA with some studies including multiple modalities) considered in the qualitative data synthesis. Pooling of the raw data in a meta-analysis demonstrated sensitivities of 0.76 (0.72-0.80), 0.78(0.70-0.84), and 0.89 (0.81-0.95) for MRI, MRA, and CT arthrogram, respectively, with specificities of 0.82 (0.77-0.86), 0.85 (0.77-0.92), and 0.89 (0.81-0.95), respectively. Additionally, across all imaging modalities, diagnostic accuracy was highest for central TFCC lesions versus peripheral lesions. Conclusion This study represents the largest meta-analysis to date to compare multiple imaging modalities for the diagnosis of TFCC injuries. Pooled data demonstrated that CTA and MRA had statistically equivalent sensitivity and specificity for the diagnosis of TFCC injuries. Diagnostic accuracy was highest for central TFCC injuries.
More Related Videos
06:26Meta-analysis of Voxel-Based Neuroimaging Studies using Seed-based d Mapping with Permutation of Subject Images SDM-PSI
Published on: November 27, 2019
04:34Meta-Analysis of the Effectiveness and Safety of Shugan Jieyu Capsules for the Treatment of Insomnia
Published on: February 17, 2023
Related Concept Videos
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Sensory Modalities
General senses refer to the broad category of sensory information detected by receptors in the body and can be further grouped into somatic and visceral senses. Somatic sensations include touch, pressure, temperature, and pain and are essential for navigating our environment and...
Directing Effect of Substituents: meta-Directing Groups
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons