Osteoarthritis is associated with increased failure of proximal femoral fracture fixation
Related Experiment Video
Updated: Feb 8, 2026

Orthopedic Robot-Assisted Femoral Neck System in the Treatment of Femoral Neck Fracture
Published on: March 3, 2023
Charles A Gallagher1, Christopher W Jones2, Lara Kimmel3,4
1Department of Orthopaedics, Fremantle Hospital, Alma Street, Fremantle, WA, 6160, Australia. gallaghercharles@hotmail.com.
Purpose:
The purpose of this study was to evaluate whether the presence of hip osteoarthritis at the time of hip fracture increases treatment failure rates when using either a sliding hip screw (SHS) or proximal femoral nail (PFN) for fracture fixation.
Methods:
A retrospective study of a consecutive series of 455 women and 148 men (median age, 83.8 years) treated with SHS or PFN was performed. Osteoarthritis was evaluated based on pre-operative radiographs using the Kellgren and Lawrence grading system. Treatment failure, which was defined as non-union, avascular necrosis, backing out of the implant, cut out of the proximal screws, peri-prosthetic fracture, implant breakage, or conversion to hemi- or total hip arthroplasty, was evaluated for a follow-up period of four to seven years. Optimal placement of the implant (tip-apex distance (TAD) and 3-point fixation) and the effects of age, sex, the quality of reduction, implant type, fracture stability, fracture type, and time to failure were considered confounders of the relationship between failure and osteoarthritis (OA).
Results:
Among the 32 cases (5.3%) of treatment failure, 12 (2%) showed evidence of osteoarthritis. After controlling for age, sex, the quality of reduction, implant type, fracture stability, fracture type, and TAD, osteoarthritis was associated a greater than threefold increase in treatment failure compared with that of patients without pre-operative evidence of osteoarthritis (OR, 3.26; 95% CI, 1.4-7.65; P = 0.006).
Conclusions:
After adjusting for potential confounding factors, radiographic evidence of hip osteoarthritis at the time of hip fracture increases the incidence of treatment failure.
Related Concept Videos
Increasing Function
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Increased Body Temperature
Increased pulse rate
Many factors can elevate the risk of developing tachycardia. These include advanced age, a family history of arrhythmias, and an...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Carbon-dioxide Fixation