Reproduction accuracy of articulator mounting with an arbitrary face-bow vs. average values-a controlled, randomized,
M Oliver Ahlers1,2, Daniel Edelhoff3, Holger A Jakstat4
1Department of Prosthetic Dentistry, School of Dental and Oral Medicine, University Hospital Hamburg-Eppendorf, University of Hamburg, Hamburg, Germany. Ahlers@UKE.de.
Objectives:
The benefit from positioning the maxillary casts with the aid of face-bows has been questioned in the past. Therefore, the aim of this study was to investigate the reliability and validity of arbitrary face-bow transfers compared to a process solely based on the orientation by means of average values. For optimized validity, the study was conducted using a controlled, randomized, anonymized, and blinded patient simulator study design.
Material And Methods:
Thirty-eight undergraduate dental students were randomly divided into two groups; both groups were applied to both methods, in opposite sequences. Investigated methods were the transfer of casts using an arbitrary face-bow in comparison to the transfer using average values based on Bonwill's triangle and the Balkwill angle. The "patient" used in this study was a patient simulator. All casts were transferred to the same individual articulator, and all the transferred casts were made using type IV special hard stone plaster; for the attachment into the articulator, type II plaster was used. A blinded evaluation was performed based on three-dimensional measurements of three reference points.
Results:
The results are presented three-dimensionally in scatterplots. Statistical analysis indicated a significantly smaller variance (Student's t test, p < 0.05) for the transfer using a face-bow, applicable for all three reference points.
Conclusions:
The use of an arbitrary face-bow significantly improves the transfer reliability and hence the validity.
Clinical Relevance:
To simulate the patient situation in an individual articulator correctly, casts should be transferred at least by means of an arbitrary face-bow.
More Related Videos
11:12Driving Simulation in the Clinic: Testing Visual Exploratory Behavior in Daily Life Activities in Patients with Visual Field Defects
Published on: September 18, 2012
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Blind Procedures
Articulations of the Vertebral Column
Blinding
Reproductive Cloning
Somatic Cell Nuclear Transfer
In SCNT, an egg cell is taken from an animal and its nucleus is removed, creating an enucleated egg. Then a somatic...
Biodiversity and Human Values