Aims:
MEDI0382 is a balanced glucagon-like peptide-1/glucagon receptor dual agonist under development for the treatment of type 2 diabetes mellitus and non-alcoholic steatohepatitis. The primary objective was to assess the safety of MEDI0382 in healthy subjects.
Methods:
In this placebo-controlled, double-blind, Phase 1 study, healthy subjects (aged 18-45 years) were randomized (3:1) to receive a single subcutaneous dose of MEDI0382 or placebo after ≥8 h of fasting. The study consisted of six cohorts that received study drug at 5 μg, 10 μg, 30 μg, 100 μg, 150 μg or 300 μg. The primary objective was safety and tolerability. Secondary endpoints included assessments of pharmacokinetics and immunogenicity. All subjects were followed for up to 28 days.
Results:
A total of 36 subjects received MEDI0382 (n = 6 per cohort) and 12 subjects received placebo (n = 2 per cohort). Treatment-emergent adverse events (TEAEs) occurred more frequently with MEDI0382 vs. placebo, which was mostly due to an increased occurrence at MEDI0382 doses ≥150 μg. All TEAEs were mild or moderate in severity. The most common TEAEs were vomiting, nausea and dizziness. There appeared to be a dose-dependent increase in heart rate with MEDI0382 treatment. MEDI0382 showed linear pharmacokinetic profile (time to maximum plasma concentration: 4.50-9.00 h; elimination half-life: 9.54-12.07 h). No immunogenicity was observed in the study.
Conclusions:
In this single-dose, Phase 1 study in healthy subjects, the safety and pharmacokinetic profiles of MEDI0382 support once-daily dosing and further clinical development of MEDI0382.
Related Concept Videos
Glucagon-like Receptor Agonists
GLP-1, when administered in high doses intravenously, triggers insulin secretion, inhibits glucagon release, slows gastric emptying, reduces food intake, and restores normal insulin secretion. However, its rapid inactivation by...
Bioavailability Study Design: Healthy Subjects Versus Patients
Bioavailability Study Design: Single Versus Multiple Dose Studies
Chemotherapy-Induced Nausea and Vomiting: Neurokinin-1 Receptor Antagonists
Drug-Receptor Interaction: Agonist
Agonists can bind to receptors in different ways. Some agonists bind directly to the receptor's active site, mimicking the endogenous...
SN1 Reaction: Stereochemistry
In the first step of an SN1 reaction, the bond between the electrophilic carbon and the leaving group ionizes to generate the carbocation intermediate. The second step of the mechanism is the nucleophilic attack.
In the formed carbocation, the positively charged carbon is sp2 hybridized with a trigonal planar geometry. As all the three substituents lie on the same plane, a plane of symmetry for the...