Gantry rotational motion-induced blur in cone-beam computed tomography
J Krebs1, A Shankar1, D R Bednarek1
1Toshiba (Canon) Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
Abstract:
As neuro-endovascular image-guided interventions (EIGIs) make use of higher resolution detectors, gantry rotational motion-induced blur becomes more noticeable in acquired projections as well as reconstructed images by reducing the visibility of vascular and device features whose visualization could be critical in the treatment of vascular pathology. Motion-induced blur in projections views is a function of an object's position in the field-of-view (FOV), gantry rotational speed, and frame capture or exposure time. In this work different frame rates were used to investigate the effects of blurring from individual projections on the reconstructed image. To test the effects of these parameters on reconstructed images, a regular pattern phantom of small objects was simulated and projection views were generated at various different frame rates for a given simulated rotational velocity. The reconstruction was made using a linear interpolation of filtered backprojections. Images reconstructed from lower frame rates showed significant blurring in the azimuthal direction, increasingly worse towards the periphery of the image. However, those reconstructed from higher frame rates showed significantly less blur throughout the entire FOV. While lower frame rates could be used with slower gantry speeds this would increase the risk of voluntary or involuntary patient motion contributing to blur over the entire FOV. A high frame rate used with high gantry speeds could reliable provide images without gantry-motion blur while reducing the risk of patient-motion blur. Frame rates exceeding 2000 fps available with photon counting detectors such as the X-counter Actaeon1 are available.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Work and Power for Rotational Motion
Similarly, the power delivered to a system that is rotating about a fixed axis...
Rotational Motion about a Fixed Axis
Work-Energy Theorem for Rotational Motion
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...