Related Experiment Video
Updated: Feb 8, 2026

Simultaneous Isolation and Culture of Atrial Myocytes, Ventricular Myocytes, and Non-Myocytes from an Adult Mouse Heart
Published on: June 14, 2020
QT correction across the heart rate spectrum, in atrial fibrillation and ventricular conduction defects
Bert Vandenberk1,2, Eline Vandael3, Tomas Robyns1,2
1Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium.
Background:
Incorporation of QTc in clinical decision support systems requires accurate QT-interval correction, also during common electrocardiogram abnormalities as ventricular conduction defects (VCD). We compared the performance and predictive value of QT correction formulas to design a patient-specific QT correction algorithm (QTcA).
Methods:
The first ECG in adult patients with sinus rhythm (SR), atrial fibrillation (AF), and ventricular pacing (VP) was collected retrospectively. QT correction was performed with Bazett (QTcB), Fridericia (QTcFri), Framingham, Hodges, and Rautaharju (QTcR) formulas. Correction formulas were compared using QTc/RR linear regression. Adjusted Cox regression was performed to predict 1-year all-cause mortality.
Results:
A total of 49,737 patients were included (70.0% SR, 24.1% AF, 5.9% VP, 11.1% VCD). Overall 1-year all-cause mortality rate was 11.8%. In patients without VCD or VP, QTcFri showed significantly better heart rate correction, both overall (P < 0.001) and in subgroups by heart rate (bradycardia P ≤ 0.001, normal P ≤ 0.050, tachycardia P ≤ 0.010). Furthermore, QTcFri improved mortality prediction significantly when compared to QTcB (P < 0.001). Patients with VCD or VP QTcR, including correction for QRS duration, had a significant better heart rate correction than QTcB (P ≤ 0.010) and improved mortality prediction significantly compared to all other formulas (P < 0.001). Implementing QTcA, designed based on QTcFri and QTcR depending on the presence of VCD or VP, reduced the patients considered to be at risk by 61.1% when compared to QTcB.
Conclusions:
A patient-specific QT correction algorithm would combine accurate heart rate correction, improved predictive value of mortality, and a reduction of patients considered to be at risk.
Related Concept Videos
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...

