Curvelet Transform-based volume fusion for correcting signal loss artifacts in Time-of-Flight Magnetic Resonance
Ahmadreza Baghaie1, Susanne Schnell2, Ali Bakhshinejad3
1Weldon School of Biomedical Engineering, Purdue University, United States.
Abstract:
Flow fields in cerebral aneurysms can be measured in vivo with phase-contrast MRI (4D Flow MRI), providing 3D anatomical magnitude images as well as 3-directional velocities through the cardiac cycle. The low spatial resolution of the 4D Flow MRI data, however, requires the images to be co-registered with higher resolution angiographic data for better segmentation of the blood vessel geometries to adequately quantify relevant flow descriptors such as wall shear stress or flow residence time. Time-of-Flight Magnetic Resonance Angiography (TOF MRA) is a non-invasive technique for visualizing blood vessels without the need to administer contrast agent. Instead TOF uses the blood flow-related enhancement of unsaturated spins entering into an imaging slice as means to generate contrast between the stationary tissue and the moving blood. Because of the higher resolutions, TOF data are often used to assist with the segmentation process needed for the flow analysis and Computational Fluid Dynamics (CFD) modeling. However, presence of slow moving and recirculating blood flow such as in brain aneurysms, especially regions where the blood flow is not perpendicular to the image plane, causes signal loss in these regions. In this work a 3D Curvelet Transform-based image fusion approach is proposed for signal loss artifact reduction of TOF volume data. Experiments show the superiority of the proposed approach in comparison to other multi-resolution 3D Wavelet-based image fusion methodologies. The proposed approach can further facilitate model-based fluid analysis and pre/post-operative treatment of patients with brain aneurysms.
Related Concept Videos
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Magnetic Resonance Imaging
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Basic signals of Fourier Transform
The sinc function, defined as sinc(x) = sin(πx)/(πx), is particularly notable for its symmetry and behavior at...
Atomic Nuclei: Magnetic Resonance
Continuous -time Fourier Transform