Related Experiment Video
Updated: Feb 8, 2026

Visualization of Germinosomes and the Inner Membrane in Bacillus subtilis Spores
Published on: April 15, 2019
Synergistic effect of combined UV-LED and chlorine treatment on Bacillus subtilis spore inactivation
Guo-Qiang Li1, Zheng-Yang Huo1, Qian-Yuan Wu2
1Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China.
Abstract:
An ultraviolet (UV)-based advanced oxidation process (AOP) for disinfecting water is introduced in this paper. This study aimed to evaluate the potential of UV light-emitting diodes (UV-LEDs)/chlorine AOP (UV/Cl2) for Bacillus subtilis spore inactivation. Chlorine was combined with 265 and 280 nm LEDs (UV265/Cl2, UV280/Cl2) and investigated. The addition of 4.0 mg/L of free chlorine at pH 7.0 in the presence of 125 mJ/cm2 of UV irradiation resulted in an additional 1.8-log reduction in UV265/Cl2 and 1.5-log reduction in UV280/Cl2. There was no observed enhancement in spore inactivation with the addition of a radical scavenger, t-BuOH, which indicated the role of •OH in the synergistic effect. To quantitatively evaluate the synergism, the primary treatment with UV/Cl2 was followed by further UV or Cl2 treatment. After UV/Cl2 pretreatment at different pH levels, the 265 and 280 nm LEDs treatment enhanced an approximate 0.4-0.5-log reduction compared to UV only, and Cl2 treatment enhanced an approximate 0.7-1.1-log reduction compared to Cl2 only. In addition, at pH 7.0, in UV265/Cl2-Cl2 and UV280/Cl2-Cl2, the inactivation rate constant k increased by approximately 2 and 1.5 times, respectively. The CT for the lag phases (CTlag) reduced to approximately 67 and 58%, respectively. Similar results were obtained at pH 7.5 and 8.0, and in the secondary effluent. The synergistic effect on spore inactivation suggested that the pathogen inactivation efficiency of sequential UV and chlorine disinfection processes, which are commonly applied, can be significantly enhanced by adding chlorine prior to UV treatment.
More Related Videos
10:03Investigating the Detrimental Effects of Low Pressure Plasma Sterilization on the Survival of Bacillus subtilis Spores Using Live Cell Microscopy
Published on: November 30, 2017
06:39Improvement of Bacillus subtilis Spore Enumeration and Label Analysis in Flow Cytometry
Published on: June 30, 2023
Related Concept Videos
X-Inactivation
Radical Substitution: Allylic Chlorination
Activation and Inactivation of G Proteins
Electrophilic Aromatic Substitution: Chlorination and Bromination of Benzene
UV–Vis Spectrum
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
UV–Vis Spectrometers