Use of reprocessed external fixators in orthopaedic surgery: a survey of 243 orthopaedic trauma surgeons
Related Experiment Video
Updated: Feb 8, 2026

Principles of Rodent Surgery for the New Surgeon
Published on: January 6, 2011
Sorawut Thamyongkit1,2, Malick Bachabi1, John M Thompson1
11Department of Orthopaedic Surgery, The Johns Hopkins University/Johns Hopkins Bayview Medical Center, 4940 Eastern Ave., Baltimore, MD 21224 USA.
Background:
The increasing financial burden of orthopaedic implants on our health care system has prompted cost-control measures, such as implant reprocessing. The purpose of this study was to describe the current usage by orthopaedic trauma surgeons of reprocessed external fixators (EFs) for treatment of complex fractures.
Methods:
A 16-question survey about use and perceptions of reprocessed EFs was distributed to 894 Orthopaedic Trauma Association members between August 2016 and June 2017 using a web-based survey system.
Results:
The authors received 243 responses (27%). Thirty-seven percent of respondents reported using reprocessed EFs. Nonprofit hospitals used reprocessed EFs more commonly than did for-profit hospitals (41% vs 15%, P = .0004). Eighty-seven percent of respondents believed reprocessing could be cost-effective. The most common reason (32%) for not using reprocessed EFs was coordination/logistics of reprocessing. Concern about litigation was also reported as a main reason for not using (20%) or having recently stopped using (21%) reprocessed EFs.
Conclusions:
Many orthopaedic traumatologists are interested in the reprocessing of EF components but few have reprocessing systems in place at their institutions. A major barrier to implementation is concern about litigation, which is likely unwarranted on the basis of Food and Drug Administration approval and a lack of previous litigation. Reprocessing by the original device manufacturers has yielded substantial savings at our institution and is an example of the cost savings that can be expected when implementing an EF reprocessing system.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
18:40Combined In vivo Optical and µCT Imaging to Monitor Infection, Inflammation, and Bone Anatomy in an Orthopaedic Implant Infection in Mice
Published on: October 16, 2014
Related Concept Videos
Surveys
Introduction to Surveying, Plane Surveying and Geodetic Surveys
Errors and Mistakes in Surveying
Types of Surveys
Survey Safety
Work Done on a System by External Force
In the presence of a non-conservative opposing force, like friction, some part of the work done...