Related Experiment Video
Updated: Feb 8, 2026

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Comparison of preoperative and postoperative measurements of optical low-coherence reflectometry biometry and
İrfan Akalın1, Melek Tüfek2, Mustafa Türkyılmaz3
1Artvin State Hospital, Artvin, Turkey. irfan_akalin@yahoo.com.
Purpose:
To compare the preoperative and postoperative measurements of optical low-coherence reflectometry (OLCR) biometry and assessment of its refractive predictability.
Methods:
A total of 114 eyes of 102 patients who underwent cataract treatment were prospectively examined. The axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), K (keratometry) 1, K2, K average (KAVE) and K astigmatic (KAST) values were recorded using Lenstar LS 900 (Haag-Streit, Koeniz, Switzerland) OLCR device. The IOL (intraocular lens) power was measured based on the SRK/T formula. The cases were divided into three subgroups according to AL (Group 1: AL < 22 mm, Group 2: 22 mm ≤ AL < 24 mm, Group 3: 24 mm ≤ AL). The mean absolute error (MAE) calculated for each eye.
Results:
The right eyes of 45 patients (44.1%), left eyes of 45 patients (44.1%), and both eyes of 12 patients (11.7%) were examined. The average AL in the preoperative period was 23.19 ± 1.01; it was 23.20 ± 0.99 in the postoperative period (p > 0.05). A significant deepening was detected in the postoperative ACD (preop 2.76 ± 0.38 mm, postop 3.81 ± 0.46 mm, p < 0.001). CCT was measured as 521.4 ± 36.3 µm in the preoperative period and as 530.8 ± 42.8 (p > 0.05) µm in the postoperative period. The average mean absolute error (MAE) was measured as 0.48 ± 0.41 D, whereas refractive error was - 0.081 ± 0.67 D. The MAE distribution of cases was found to be ≤ 1.5 D 109 (95.6%) eyes, and ≤ 2.0 D in 114 (100%) eyes. MAE values according to AL of the cases were calculated as 0.71 ± 0.83 D in group 1, 0.49 ± 0.43 D in group 2 and 0.41 ± 0.36 D in group 3 (p > 0.05).
Conclusion:
When the measurement and refractive results of the OLCR biometry were evaluated, it was observed that there was a very satisfactory result and a predictable device compatible with the current literature. The SRK/T formula, one of the new generation formulas, has shown high MAE and RE results in eyes with AL ≤ 22 mm, although not statistically significant. Other new generation formulas should be tried in these eyes.
More Related Videos
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Predicting Molecular Geometry
Prediction Intervals
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Influence of Earth's Curvature and Atmospheric Refraction on Leveling
End Point Prediction: Gran Plot
For potentiometric titration, the Gran plot is created by plotting...

