Measurement duration affects the calculation of whole body protein turnover kinetics but not between-day variability
Leonie C Ruddick-Collins1, Neil A King1, Nuala M Byrne2
1Institute of Health and Biomedical Innovation, School of Exercise and Nutrition Sciences, Queensland University of Technology, 60 Musk Avenue, Kelvin Grove, QLD 4059, Australia.
Background:
Assessment of whole body protein turnover (WBPT) can provide fundamental information about protein kinetics which underpins the conservation of lean tissue. Reliability and methodology studies on the measurement of WBPT are scarce. This study aimed to assess the effects of urine collection duration (9 versus 12 h) and the reproducibility of WBPT with the end product method calculated from ammonia as the end product.
Methods:
WBPT was assessed in 21 healthy participants (11M, 10F) on 2 test days. WBPT was assessed using the end product method with a single dose of 15N glycine with ammonia as end product in a postprandial state with 9 and 12-h urine collections.
Results:
The CV for protein flux averaged 10% and 12% for 9 and 12-h urine collections respectively. Protein flux, synthesis and balance were significantly higher and protein breakdown significantly lower with 9-h urine collections compared to 12-h collections (P < 0.01) and there was a trend towards increasingly greater overestimation of 9-h calculated WBPT kinetics with greater overall rates of WBPT. Correlations between the 9 and 12-h values were strong (r > 0.962, P < 0.001 for all variables).
Conclusions:
The reproducibility of WBPT with ammonia as the end product was similar to previously reported reproducibility of the gold standard precursor technique. The use of a 12-h urine collection is more effective to achieve full turnover of the ammonia free amino acid (AA) pool.
Related Concept Videos
Kinetic Energy for a Rigid Body
Enzyme Kinetics
Scientists typically study enzyme kinetics with a fixed amount of enzyme in the controlled environment of a test tube. When more reactant, or substrate, is...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Role of Proteins in the Human Body
Kinetic Energy
Protein-Drug Binding: Mechanism and Kinetics
Various forces drive these interactions, including hydrogen bonds, hydrophobic interactions, ionic bonds, electrostatic interactions, and van der Waals forces. These bonds enable drugs to bind to specific sites on proteins,...