Related Experiment Video
Updated: Feb 8, 2026

Assessment of the Efficacy of An Osteopathic Treatment in Infants with Biomechanical Impairments to Suckling
Published on: February 5, 2019
Assessment of Biomechanical Changes After Sacroiliac Joint Fusion by Application of the 3-Dimensional Motion Analysis
Je Hoon Jeong1, Jeremi M Leasure2, Jon Park3
1Department of Neurosurgery, Soonchunhyang University Bucheon Hospital, Bucheon, Republic of Korea.
Background:
Sacroiliac (SI) joint motion is complex and is poorly understood overall. In this study we evaluated a new biomechanical method developed to provide more insight into SI joint movement and to elucidate biomechanical changes after SI joint fusion surgery in a one-leg standing model.
Methods:
Eight lumbosacral cadaver specimens (L5-pelvis specimens, age 28-57 years, 6 female and 2 male) were used in this experiment. We analyzed the changes in range of motion (ROM) in single-plane motion and mobility in 3 groups of patients: intact, unilateral fusion, and bilateral fusion groups. For statistical analysis, we used repeated-measures analysis of variance to compare SI joint ROM among the 3 groups. iFuse implants were prepared using the standard posterior placement technique. Pure-moment multidirectional bending tests were performed in each direction (nutation and counternutation, axial rotation, and lateral bending).
Results:
Average ROM in single-plane motion and mobility of the intact SI joint were 4.5 ± 3.3° and 4.8 ± 3.4°, respectively in nutation-counternutation; 2.9 ± 2.1° and 3.3 ± 2.3°, respectively, in axial rotation; and 1.5 ± 1.5° and 2.8 ± 2.5°, respectively, in lateral bending. We observed statistically significantly (P = 0.05) greater mobility in lateral moment testing than in single motion testing. Comparisons among the intact, unilateral fusion, and bilateral fusion groups showed statistically significant differences in the lateral moment test.
Conclusions:
This study suggests that our new biomechanical method for SI joint evaluation may provide improved insight into SI joint movement and biomechanical changes after SI joint fusion surgery in a one-leg standing model.
More Related Videos
09:37Substantiating Appropriate Motion Capture Techniques for the Assessment of Nordic Walking Gait and Posture in Older Adults
Published on: May 12, 2016
08:27Three-Dimensional Finger Motion Tracking during Needling: A Solution for the Kinematic Analysis of Acupuncture Manipulation
Published on: October 28, 2021
Related Concept Videos
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Dimensional Analysis
In fluid mechanics, dimensional...
Dimensional Analysis
Dimensional analysis allows us to analyze and compare physical quantities on a...
Dimensional Analysis
Dynamics Of Circular Motion: Applications
Application of Antiderivatives: Linear Motion