Related Experiment Video
Updated: Feb 8, 2026

Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
Bioelectrical impedance analysis; a new method to evaluate lymphoedema, fluid status, and tissue damage after
Madeleine Asklöf1, Preben Kjølhede1, Ninnie Borendal Wodlin1
1Department of Obstetrics and Gynaecology, Department of Clinical and Experimental Medicine, Faculty of Medicine and Health Science, Linköping University, Linköping, Sweden.
Abstract:
The aim of this descriptive review is to summarise the current knowledge of non-invasive bioelectrical impedance analysis (BIA) used with gynaecological surgical patients in regard to postoperative development of lymphoedema and determination of perioperative fluid balance, and as a prognostic factor in cancer mortality and a predictor of postoperative complications. The databases PubMed, MEDLINE, Scopus Web of Science, the Cochrane Library, and reference lists of selected articles were searched for relevant articles published during the period January 2008-April 2018. Only papers published in English were retrieved. Thirty-seven articles were evaluated. Where gynaecological studies were lacking, studies with a study population from neighbouring clinical fields were used instead. Studies on the clinical use of BIA with gynaecological surgical patients were divided into three categories: the postoperative development of lower limb lymphoedema (n = 7), perioperative hydration measuring (n = 3), and the BIA parameter phase angle as a prognostic factor in cancer survival and as predictive for postoperative complications (n = 6). Of these 16 studies only three used a pure gynaecological study population. Three different methods of BIA were used in these articles: single frequency-BIA, multifrequency-BIA and bioimpedance spectroscopy. BIA was found to detect lymphoedema with a sensitivity of 73% and a specificity of 84%. Studies indicated that BIA was able to detect lower limb lymphoedema at an early stage even before it became clinically detectable. During postoperative hydration measurements, an increase in extracellular fluid volume and extracellular fluid volume in relation to total body fluid volume, as well as a decrease in phase angle, were associated with higher frequencies of postoperative complications. Moreover, low values for the phase angle have been associated with increased mortality in cancer patients. However, the number of studies in this field was limited. From our review, BIA seems to be a useful tool for use in the clinical setting of the gynaecological surgical patient. The theoretical approach of using bioelectrical impedance values to measure the fluid distribution in the body compartments offers wide opportunities in the clinical setting. However, so far, all studies have set up cut-off limits within the study population, and reference values for a general population need to be defined. There are also rather few studies on a gynaecological study population. Hence, there is a need for further studies within gynaecological surgery focusing on early detection of lower limb lymphoedema, perioperative fluid balance, and postoperative complications in order to establish the value of BIA in clinical praxis.
More Related Videos
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
07:44Author Spotlight: Implementation of BIVA for Analyzing Disease Risk Factors in Patients with Low Body Cell Mass
Published on: July 14, 2023
Related Concept Videos
Systematic Sampling Method
Systematic sampling is one of the simplest methods...
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Fluid Connective Tissues: Blood and Lymph
Blood
The blood flows through blood vessels— arteries, capillaries, and veins. Blood plasma is primarily made of proteins, solutes, and...
Impedance Combination
Random and Systematic Errors