Influence of Accelerometer Calibration Approach on Moderate-Vigorous Physical Activity Estimates for Adults
Charles E Matthews1, Sarah Kozey Keadle1,2, David Berrigan3
1Metabolic Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Bethesda, MD.
Purpose:
To compare estimates of moderate-vigorous physical activity (MVPA) duration derived from accelerometers calibrated only to walking and running activities to estimates from calibrations based on a broader range of lifestyle and ambulatory activities.
Methods:
In a study of 932 older (50-74 yr) adults we compared MVPA estimates from accelerometer counts based on three ambulatory calibration methods (Freedson 1952 counts per minute; Sasaki 2690 counts per minute; activPAL 3+ METs) to estimates based on calibrations from lifestyle and ambulatory activities combined (Matthews 760 counts per minute; Crouter 3+ METs; Sojourn3x 3+ METs). We also examined data from up to 6 previous-day recalls describing the MVPA in this population.
Results:
The MVPA duration values derived from ambulatory calibration methods were significantly lower than methods designed to capture a broader range of both lifestyle and ambulatory activities (P < 0.05). The MVPA (h·d) estimates in all participants were: Freedson (median, 0.35; interquartile range, 0.17-0.58); Sasaki (median, 0.91; interquartile range, 0.59-1.32); and activPAL (median, 0.97; interquartile range, 0.71-1.26) compared with Matthews (median, 1.82; interquartile range, 1.37-2.34); Crouter (2.28 [1.72-2.82]); and Sojourn3x (median, 1.85; interquartile range, 1.42-2.34). Recall-based estimates in all participants were comparable (median, 1.61; interquartile range, 0.89-2.57) and indicated participation in a broad range of lifestyle and ambulatory MVPA.
Conclusions:
Accelerometer calibration studies that employ only ambulatory activities may produce MVPA duration estimates that are substantially lower than methods calibrated to a broader range of activities. These findings highlight the potential to reduce potentially large differences among device-based measures of MVPA due to variation in calibration study design by including a variety of lifestyle and ambulatory activities.
Related Concept Videos
Estimation of the Physical Quantities
Factors Influencing Attraction II: Physical Attraction
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
What are Estimates?
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...
Physical and Chemical Properties of Matter