Abstract:
Individuals who have lost normal pathways for communication need augmentative and alternative communication (AAC) devices. In this study, we propose a new electrooculogram (EOG)-based human-computer interface (HCI) paradigm for AAC that does not require a user's voluntary eye movement for binary yes/no communication by patients in locked-in state (LIS). The proposed HCI uses a horizontal EOG elicited by involuntary auditory oculogyric reflex, in response to a rotating sound source. In the proposed HCI paradigm, a user was asked to selectively attend to one of two sound sources rotating in directions opposite to each other, based on the user's intention. The user's intentions could then be recognised by quantifying EOGs. To validate its performance, a series of experiments was conducted with ten healthy subjects, and two patients with amyotrophic lateral sclerosis (ALS). The online experimental results exhibited high-classification accuracies of 94% in both healthy subjects and ALS patients in cases where decisions were made every six seconds. The ALS patients also participated in a practical yes/no communication experiment with 26 or 30 questions with known answers. The accuracy of the experiments with questionnaires was 94%, demonstrating that our paradigm could constitute an auxiliary AAC system for some LIS patients.
More Related Videos
12:07Using an EEG-Based Brain-Computer Interface for Virtual Cursor Movement with BCI2000
Published on: July 29, 2009
07:26Characterizing the Relationship Between Eye Movement Parameters and Cognitive Functions in Non-demented Parkinson's Disease Patients with Eye Tracking
Published on: September 26, 2019
Related Concept Videos
Communication
Communication
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Protein-protein Interfaces
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...