Mechanical solutions to salvage failed distraction osteogenesis in large bone defect management
Dmitry Y Borzunov1, Alexander L Shastov2
1Russian Ilizarov Scientific Center for Restorative Traumatology and Orthopaedics, 6, M. Ulianova Street, Kurgan, 640014, Russian Federation. borzunov@bk.ru.
Introduction:
Ilizarov bone transport for large bone defect is challenging and may end in distraction osteogenesis failure.
Material And Methods:
Ten forearm and seven tibial defect cases with failed regeneration due to ischaemia during bone transport were studied retrospectively. Mean forearm and tibial defects were 5.5 ± 0.8 and 7.6 ± 1 cm respectively, or 22.3 ± 3.6 and 20 ± 2.3% as compared with healthy segments. Most patients had numerous previous operations (2.6 ± 0.5 and 3.4 ± 0.8 per patient, respectively), extensive scars locally and post-traumatic neuropathy. There were seven infected defects. Mechanical solutions used were (1) additional osteotomy and transport of the fragment to compact the ischaemic regenerate (10 forearms, 4 tibias) and (2) compaction of the connective tissue layer in the tibial regenerate with either two 5-mm steps (two cases) or gradually (one case).
Results:
Bone integrity was restored in all the cases. Complete compensation of the defects was achieved in 12 patients with the first technique. Two patients with 8-cm ulna defects remained with residual discrepancy. In the forearm, mean compaction was 1.7 ± 0.4 cm. It took 25.7 ± 5.4 days followed by an average fixation period of 107.1 ± 11.8 days. In the tibia, mean longitudinal compaction by distraction measured 1.7 ± 0.8 cm. The second technique ended up with an acceptable shortening of 1 cm in two cases. Four centimeters were compressed in the third case gradually.
Conclusion:
The technical solutions used for mechanical effects on the ischaemic distraction regenerate resulted in its rescue and bone union in all the cases.
Related Concept Videos
Hypothesis: Accept or Fail to Reject?
There are two ways to indicate that the null hypothesis is not rejected. 'Accept' the null...
Lumber Defects
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...
Ideal Solutions
General Properties of Solutions
Solution Formation
This selective...
Enthalpy of Solution